PubMed 文献 · Br J Radiol · 2021-03-11

ADC图和T2WI的Energy、Inertia、Correlation在五组间有统计学差异;ADC-energy和T2-energy是GGG趋势的独立预测因子。ADC-energy对GGG1的诊断AUC为84.6%,敏感度88.9%、特异度95.1%。

要点

  • ADC-energy是GGG趋势的独立预测因子,对GGG1诊断AUC 84.6%,敏感度88.9%、特异度95.1%。
  • T2WI-correlation对GGG1诊断AUC 83.5%,T2WI-energy AUC 74.3%。
  • ADC图和T2WI的Energy、Inertia、Correlation在五个GGG组间有统计学差异。

诊断标准与关键数值

  • ADC-energy诊断GGG1的AUC为84.6%,敏感度88.9%,特异度95.1%。
  • T2WI-energy诊断GGG1的AUC为74.3%。
  • T2WI-correlation诊断GGG1的AUC为83.5%。
  • ADC-energy和T2-energy是GGG趋势的独立预测因子。
  • ADC-energy、T2WI-energy和T2WI-correlation在GGG1与GGG2-5之间有统计学差异。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To explore the potential value of multiparametric magnetic resonance imaging (mpMRI) texture analysis (TA) to predict new Gleason Grade Group (GGG).

METHODS: Fifty-eight lesions of fifty patients who underwent mpMRI scanning, including T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) prior to trans-rectal ultrasound (TRUS)-guided core prostate biopsy, were retrospectively enrolled. TA parameters were obtained by the postprocessing software, and each lesion was assigned to its corresponding GGG. TA parameters derived from T2WI and DWI were statistically analyzed in detail.

RESULTS: Energy, inertia, and correlation derived from apparent diffusion coefficient (ADC) maps and T2WI had a statistically significant difference among the five groups. Kurtosis, energy, inertia, correlation on ADC maps and Energy, inertia on T2WI were moderately related to the GGG trend. ADC-energy and T2-energy were significant independent predictors of the GGG trend. ADC-energy, T2WI-energy, and T2WI-correlation had a statistically significant difference between GGG1 and GGG2-5. ADC-energy were significant independent predictors of the GGG1. ADC-energy, T2WI-energy, and T2WI-correlation showed satisfactory diagnostic efficiency of GGG1 (area under the curve (AUC) 84.6, 74.3, and 83.5%, respectively), and ADC-energy showed excellent sensitivity and specificity (88.9 and 95.1%, respectively).

CONCLUSION: TA parameters ADC-energy and T2-energy played an important role in predicting GGG trend. Both ADC-energy and T2-correlation produced a high diagnostic power of GGG1, and ADC-energy was perfect predictors of GGG1.

ADVANCES IN KNOWLEDGE: TA parameters were innovatively used to predict new GGG trend, and the predictive factors of GGG1 were screen out.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. He X, Xiong H, Zhang H, et al. Value of MRI texture analysis for predicting new Gleason grade group. Br J Radiol. 2021. PMID: 33684304. doi:10.1259/bjr.20210005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。