文献速递泌尿生殖腹部MR

ASL在检测移植肾纤维化方面优于缩减视野IVIM

Detection of renal allograft fibrosis with MRI: arterial spin labeling outperforms reduced field-of-view IVIM.
PubMed 文献 · Eur Radiol · 2021-03-18

本前瞻性研究纳入175例肾移植受者,比较缩减视野IVIM DWI与ASL评估移植肾纤维化及预测长期功能障碍的价值。ASL测量的肾血流量(RBF)在区分不同纤维化分级及预测长期功能障碍方面的AUC均高于皮质总ADC。结论认为ASL是比缩减视野IVIM更有前景的无创技术。

要点

  • ASL测量的RBF在区分无纤维化与轻度纤维化、中度与重度纤维化方面均有统计学差异。
  • RBF区分纤维化及预测长期功能障碍的AUC均高于皮质总ADC。
  • ASL可能成为无创评估移植肾纤维化和预测功能预后的更优技术。

诊断标准与关键数值

  • RBF在ci0 vs ci1为147.9 ± 46.3 vs 126.0 ± 49.4 ml/min/100 g(p = .02),ci2 vs ci3为92.9 ± 46.9 vs 70.8 ± 37.8 ml/min/100 g(p = .03)。
  • 稳定组RBF高于受损组:144.73 ± 49.33 vs 102.19 ± 47.58 ml/min/100 g(p < .001)。
  • RBF区分ci0 vs ci1-3的AUC为0.76,高于皮质ADCT的0.59(p < .001);区分ci0-1 vs ci2-3的AUC为0.79 vs 0.68(p = .01);区分ci0-2 vs ci3的AUC为0.79 vs 0.68(p = .01)。
  • RBF预测长期移植肾功能障碍的AUC为0.76,高于皮质ADCT的0.60(p = .04)。

临床应用与阅片要点

  • 日常阅片时可关注ASL获得的RBF值,其有助于区分移植肾纤维化分级。
  • RBF在预测长期移植肾功能障碍方面可能优于扩散参数,可结合临床需求考虑使用。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the value of reduced field-of-view (FOV) intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) and arterial spin labeling (ASL) for assessing renal allograft fibrosis and predicting long-term dysfunction.

METHODS: This prospective study included 175 renal transplant recipients undergoing reduced FOV IVIM DWI, ASL, and biopsies. Renal allograft fibrosis was categorized into ci0, ci1, ci2, and ci3 fibrosis according to biopsy results. A total of 83 participants followed for a median of 39 (IQR, 21-42) months were dichotomized into stable and impaired allograft function groups based on follow-up estimated glomerular filtration rate. Total apparent diffusion coefficient (ADCT), pure diffusion ADC, pseudo-perfusion ADC, perfusion fraction f from IVIM DWI, and renal blood flow (RBF) from ASL were calculated and compared. The area under the receiver operating characteristic curve (AUC) was calculated to assess the diagnostic and predictive performances.

RESULTS: RBF was different in ci0 vs ci1 (147.9 ± 46.3 vs 126.0 ± 49.4 ml/min/100 g, p = .02) and ci2 vs ci3 (92.9 ± 46.9 vs 70.8 ± 37.8 ml/min/100 g, p = .03). RBF in the stable group was higher than that in the impaired group (144.73 ± 49.33 vs 102.19 ± 47.58 ml/min/100 g, p < .001). AUCs in distinguishing renal allograft fibrosis and predicting long-term allograft dysfunction for RBF were higher than cortical ADCT (ci0 vs ci1-3, 0.76 vs 0.59, p < .001; ci0-1 vs ci2-3, 0.79 vs 0.68, p = .01; ci0-2 vs ci3, 0.79 vs 0.68, p = .01; 0.76 vs 0.60, p = .04, respectively).

CONCLUSION: Compared to reduced FOV IVIM DWI, ASL was a more promising technique for noninvasively distinguishing renal allograft fibrosis degree and predicting long-term allograft dysfunction.

KEY POINTS: • Compared to total ADC from rFOV IVIM DWI, RBF from ASL can distinguish no fibrosis (ci0) vs mild fibrosis (ci1) (p = .02) and moderate fibrosis (ci2) vs severe fibrosis (ci3) (p = .04). • RBF had superior performance than diffusion parameters in discriminating fibrosis (no fibrosis [ci0] vs fibrosis [ci1-3], mild fibrosis [ci0-1] vs moderate to severe fibrosis [ci2-3], non-severe [ci0-2] vs severe [ci3] fibrosis; AUC = 0.76 vs 0.59, p < .001; 0.79 vs 0.68, p = .01; 0.79 vs 0.68, p = .01). • Compared to reduced FOV IVIM DWI, ASL was a more promising technique for noninvasively predicting long-term allograft dysfunction (AUC = 0.76 vs 0.60, p = .04).

来源:Eur Radiol,查看原文。版权归原作者所有。