PubMed 文献 · Eur Radiol · 2021-03-13

该系统综述与Meta分析纳入12项原始研究,评估CT LI-RADS的阅片者间信度。病灶大小ICC为0.99,APHE、WO、EC的κ分别为0.69、0.67、0.65,LI-RADS分类κ为0.70。阅片者平均经验≥10年者LR的κ显著高于<10年者(0.82 vs 0.45,p=0.01),含经验不足阅片者的研究APHE和LR的κ显著低于全为有经验阅片者的研究。

要点

  • CT LI-RADS主要征象和分类的阅片者间信度达中等至较好水平。
  • 阅片者平均经验≥10年者LR的κ显著高于<10年者(0.82 vs 0.45,p=0.01)。
  • 含经验不足阅片者的研究APHE和LR的κ显著低于全为有经验阅片者的研究。

核心结论

  • CT LI-RADS对主要征象和LR分类显示中等至较好的阅片者间信度。
  • 阅片者间信度因平均阅片者经验和阅片者经验差异而显著不同。
  • 解读CT LI-RADS阅片者间信度报告时应考虑影像分析方法学。

研究设计与样本

  • 系统综述与Meta分析,检索MEDLINE和EMBASE数据库2014年1月至2020年3月,纳入12项报告CT LI-RADS阅片者间信度的原始研究。
  • 采用随机效应模型计算病灶大小、主要征象(APHE、WO、EC)和LI-RADS分类的合并ICC或κ值。
  • 对合并κ按阅片者数量、平均阅片者经验、阅片者经验差异和LI-RADS版本进行亚组分析。

诊断标准与关键数值

  • 阅片者平均经验≥10年的研究LR的κ为0.82 vs <10年者0.45(p=0.01)。
  • 含经验不足阅片者的研究APHE的κ为0.55 vs 全为有经验阅片者0.76(p=0.04),LR的κ为0.45 vs 0.79(p=0.02)。

临床应用与阅片要点

  • 阅片者经验水平可能影响CT LI-RADS主要征象判读和分类的一致性。
  • 报告CT LI-RADS结果时可参考本研究提供的各征象和分类的合并信度值。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To establish inter-reader reliability of CT Liver Imaging Reporting and Data System (LI-RADS) and explore factors that affect it.

METHODS: MEDLINE and EMBASE databases were searched from January 2014 to March 2020 to identify original articles reporting the inter-reader reliability of CT LI-RADS. The imaging analysis methodology of each study was identified, and pooled intraclass correlation coefficient (ICC) or kappa values (κ) were calculated for lesion size, major features (arterial-phase hyperenhancement [APHE], nonperipheral washout [WO], and enhancing capsule [EC]), and LI-RADS categorization (LR) using random-effects models. Subgroup analyses of pooled κ were performed for the number of readers, average reader experience, differences in reader experience, and LI-RADS version.

RESULTS: In the 12 included studies, the pooled ICC or κ of lesion size, APHE, WO, EC, and LR were 0.99 (0.96-1.00), 0.69 (0.58-0.81), 0.67 (0.53-0.82), 0.65 (0.54-0.76), and 0.70 (0.59-0.82), respectively. The experience and number of readers varied: studies using readers with ≥ 10 years of experience showed significantly higher κ for LR (0.82 vs. 0.45, p = 0.01) than those with < 10 years of reader experience. Studies with multiple readers including inexperienced readers showed significantly lower κ for APHE (0.55 vs. 0.76, p = 0.04) and LR (0.45 vs. 0.79, p = 0.02) than those with all experienced readers.

CONCLUSIONS: CT LI-RADS showed substantial inter-reader reliability for major features and LR. Inter-reader reliability differed significantly according to average reader experience and differences in reader experience. Reported results for inter-reader reliability of CT LI-RADS should be understood with consideration of the imaging analysis methodology.

KEY POINTS: • The CT Liver Imaging Reporting and Data System (LI-RADS) provides substantial inter-reader reliability for three major features and category assignment. • The imaging analysis methodology varied across studies. • The inter-reader reliability of CT LI-RADS differed significantly according to the average reader experience and the difference in reader experience.