二维剪切波弹性成像预测慢性乙型和丙型肝炎患者肝纤维化的诊断效能:组织病理学对照研究
本研究纳入103例在弹性成像检查后三个月内接受肝活检的慢性乙型和丙型肝炎成人患者,采用LOGIQ E9系统行实时二维剪切波弹性成像,以METAVIR评分为参考标准。结果显示弹性成像值与肝纤维化程度呈显著正相关(CHB Spearman系数0.76,CHC 0.83,p=0.0001),并确定了CHB和CHC各纤维化分期的刚度截断值。结论认为2D-SWE对肝纤维化诊断可靠且准确,在选定患者中可能有助于减少肝活检需求。
要点
- 2D-SWE刚度值与METAVIR纤维化分期显著正相关,CHB r=0.76、CHC r=0.83(p=0.0001)。
- CHB各期截断值:F≥1 5.92 kPa、F≥2 7.69 kPa、F≥3 8.97 kPa、F≥4 12.15 kPa。
- CHC各期截断值:F≥1 6.09 kPa、F≥2 7.81 kPa、F≥3 9.0 kPa、F≥4 12.47 kPa。
关键影像表现/征象
- 弹性成像值与肝纤维化程度呈统计学显著正相关,CHB的Spearman相关系数为0.76、CHC为0.83(p=0.0001)。
诊断标准与关键数值
- CHB患者刚度截断值:F≥1为5.92 kPa、F≥2为7.69 kPa、F≥3为8.97 kPa、F≥4为12.15 kPa。
- CHC患者刚度截断值:F≥1为6.09 kPa、F≥2为7.81 kPa、F≥3为9.0 kPa、F≥4为12.47 kPa。
临床应用与阅片要点
- 对慢性乙型或丙型肝炎患者行2D-SWE测值,可参照本研究按病因(CHB/CHC)选择对应METAVIR分期的刚度截断值。
局限性
- 原文指出需更大样本的前瞻性系列研究来证实结果并确定各纤维化分期最合适的截断值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: In this study, we investigated the diagnostic efficacy of 2D-Shear Wave Elastography (2D-SWE) in detecting stages of liver fibrosis and determining the disease-specific cut-off values in patients with chronic hepatitis B and C infection, using histopathological analysis as the reference method.
METHOD: Our study included 103 consecutive adult patients with chronic hepatitis B and C infection (CHB and CHC) who had liver biopsy within three months of elastography examination. A real-time 2D-SWE was performed using the LOGIQ E9 system (GE Medical Systems, Wisconsin, USA). The correlation between the liver stiffness measurements and the METAVIR scores was evaluated. The diagnostic performance of 2D-SWE was assessed, and cut-off values were set.
RESULTS: We found a statistically significant positive correlation between elastography values and the degree of liver fibrosis (Spearman's correlation coefficient = 0.76 and 0.83 for CHB and CHC; respectively) (p = 0.0001). The stiffness cut-off values were F ≥ 1: 5.92 kPa, F ≥ 2: 7.69 kPa, F ≥ 3: 8.97 kPa, F ≥ 4: 12.15 kPa in CHB; and F ≥ 1: 6.09 kPa, F ≥ 2: 7.81 kPa, F ≥ 3: 9.0 kPa, F ≥ 4: 12.47 kPa in CHC patients.
CONCLUSION: 2D-SWE is reliable and accurate for the diagnosis of liver fibrosis. In selected patients, 2D-SWE may be useful in reducing the need for liver biopsy when staging fibrosis. Further studies in larger prospective series are needed to confirm these results and determine the most appropriate cut-off values for each stage of liver fibrosis.
引用
- Aksakal M, Oktar SO, Sendur HN, et al. Diagnostic performance of 2D shear wave elastography in predicting liver fibrosis in patients with chronic hepatitis B and C: a histopathological correlation study. Abdom Radiol (NY). 2021. PMID: 33723676. doi:10.1007/s00261-021-03019-6