EVAR 术中基于患者个体化剂量学方法估算主要受照器官辐射剂量

A novel personalized dosimetry method for endovascular aneurysm repair (EVAR) procedures.
PubMed 文献 · Eur Radiol · 2021-03-06

前瞻性采集 8 例标准 EVAR 患者的剂量学与人体测量学数据,用患者特异性蒙特卡罗模拟估算各投射角度下透视与 DSA 采集的器官/组织剂量。皮肤、脊髓骨髓、肾、脾受照剂量最高(192.4、96.7、72.9、33.6 mGy);与标准化体模剂量学软件相比,对应剂量值差异可达 151%。

要点

  • 标准 EVAR 中皮肤、脊髓骨髓、肾、脾为受照剂量最高的器官/组织。
  • 使用标准化体模软件估算器官剂量与患者个体化方法差异可达 151%。
  • 患者体型/解剖及不同投射角度曝光参数变化影响器官剂量估算可靠性。

关键影像表现/征象

  • EVAR 中器官/组织辐射剂量最高者为皮肤 192.4 mGy、脊髓骨髓 96.7 mGy、肾 72.9 mGy、脾 33.6 mGy。
  • 心脏 6.3 mGy、肝 14.4 mGy、结肠 18.4 mGy、膀胱 14.8 mGy、胰腺 21.6 mGy、胃 11.2 mGy。
  • 采用标准化体模的对应剂量值与个体化方法估算值差异可达 151%。

临床应用与阅片要点

  • 报告 EVAR 相关辐射剂量时可关注皮肤、脊髓骨髓、肾、脾等主要受照器官/组织。
  • 采用标准化体模软件估算器官剂量时需考虑其与患者个体化方法差异可达 151%。
  • 器官剂量估算需结合患者体型/解剖及不同投射角度下曝光参数/束流角度的变化。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To estimate radiation doses for the primarily irradiated organs/tissues of patients subjected to standard endovascular aneurysm repair (EVAR) procedures using a novel personalized dosimetry method.

METHODS: Dosimetric and anthropometric data were collected prospectively for eight patients who underwent standard EVAR procedures. Patient-specific Monte Carlo simulations were performed to estimate organ/tissue doses from each of the fluoroscopic and digital subtraction angiography acquisitions involved in EVAR. Individual-specific cumulative absorbed doses were estimated for the skin, spinal bone marrow, heart, kidneys, liver, colon, bladder, pancreas, stomach, and spleen and compared to corresponding values estimated through a commercially available dosimetric software package that employs standardized phantoms.

RESULTS: The highest organ/tissue radiation doses from EVAR were found for the skin, spinal bone marrow, kidneys, and spleen as 192.4 mGy, 96.7 mGy, 72.9 mGy, and 33.6 mGy respectively, while the doses to the heart, liver, colon, bladder, pancreas, and stomach were 6.3 mGy, 14.4 mGy, 18.4 mGy, 14.8 mGy, 21.6 mGy, and 11.2 mGy respectively. Corresponding dose values using standardized phantoms were found to differ up to 151%.

CONCLUSION: Considerable radiation doses may be received by primarily exposed organs/tissues during standard EVAR. The specific size/anatomy of the patient and the variation in exposure parameters/beam angulation between different projections commonly involved in EVAR procedures should be taken into account if reliable organ dose data are to be derived.

KEY POINTS: • A novel patient-specific dosimetry method was utilized to estimate radiation doses to the primarily irradiated organs/tissues of patients subjected to standard endovascular aneurysm repair procedures. • The use of standardized mathematical anthropomorphic phantoms to derive organ dose from fluoroscopically guided procedures may result in considerable inaccuracies due to differences in the assumed organ position/volume/shape compared to patients.

来源:Eur Radiol,查看原文。版权归原作者所有。