文献速递腹部儿科影像USMR

剪切波弹性成像检测囊性纤维化儿童肝纤维化的临床研究

Clinical use of shear-wave elastography for detecting liver fibrosis in children and adolescents with cystic fibrosis.
PubMed 文献 · Pediatr Radiol · 2021-03-24

本研究在94例囊性纤维化儿童中行178次SWE检查,其中27例接受34次MR弹性成像作为参考。6-MHz点SWE与MR弹性成像相关(r=0.52),以1.45 m/s区分正常与异常MR弹性成像的敏感度79%、特异度100%、AUROC 0.94,以1.84 m/s区分轻中度与重度纤维化的敏感度88%、特异度86%、AUROC 0.79。

要点

  • 6-MHz点SWE是唯一与MR弹性成像相关的方法(r=0.52)。
  • SWE 1.45 m/s区分正常与异常MR弹性成像,特异度100%。
  • SWE 1.84 m/s区分轻中度与重度MR弹性成像,敏感度88%。

诊断标准与关键数值

  • 6-MHz点SWE以1.45 m/s区分正常与异常MR弹性成像:敏感度79%、特异度100%、PPV 100%、NPV 55%、AUROC 0.94。
  • 6-MHz点SWE以1.84 m/s区分轻中度(MR弹性成像3.00-4.77 kPa)与重度(>4.77 kPa):敏感度88%、特异度86%、PPV 78%、NPV 93%、AUROC 0.79。
  • AST/血小板比值指数0.42、fibrosis-4 0.29、GGT/血小板比值1.43对SWE>1.84 m/s均有>95%的NPV。

临床应用与阅片要点

  • 6-MHz点SWE与MR弹性成像相关,可用于筛查中评估肝硬度。
  • SWE 1.45 m/s可作为区分正常与异常MR弹性成像的参考阈值。
  • SWE 1.84 m/s可作为区分轻中度与重度MR弹性成像的参考阈值。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Complications from liver cirrhosis are a leading cause of death in children with cystic fibrosis. Identifying children at risk for developing liver cirrhosis and halting its progression are critical to reducing liver-associated mortality.

OBJECTIVE: Quantitative US imaging, such as shear-wave elastography (SWE), might improve the detection of liver fibrosis in children with cystic fibrosis (CF) over gray-scale US alone. We incorporated SWE in our pediatric CF liver disease screening program and evaluated its performance using magnetic resonance (MR) elastography.

MATERIALS AND METHODS: Ninety-four children and adolescents with CF underwent 178 SWE exams, aspartate aminotransferase (AST), alanine aminotransferase (ALT), gamma-glutamyl transferase (GGT) and platelet measurements. Of these, 27 children underwent 34 MR elastography exams. We evaluated SWE performance using 6-MHz and 9-MHZ point SWE, and 9-MHz two-dimensional (2-D) SWE.

RESULTS: The 6-MHz point SWE was the only method that correlated with MR elastography (r=0.52; 95% confidence interval [CI] 0.20-0.74; P=0.003). SWE of 1.45 m/s distinguished normal from abnormal MR elastography (79% sensitivity, 100% specificity, 100% positive predictive value [PPV], 55% negative predictive value [NPV], area under the receiver operating characteristic [AUROC] curve 0.94). SWE of 1.84 m/s separated mild-moderate (3.00-4.77 kPa) from severe (>4.77 kPa) MR elastography (88% sensitivity, 86% specificity, 78% PPV, 93% NPV, AUROC 0.79). Elevations of AST, ALT, GGT and thrombocytopenia were associated with higher SWE. AST-to-platelet ratio index of 0.42, fibrosis-4 of 0.29, and GGT-to-platelet ratio of 1.43 all had >95% NPV for SWE >1.84 m/s.

CONCLUSION: Given its correlation with MR elastography, SWE might be a clinically useful predictor of liver fibrosis. We identified imaging criteria delineating the use of SWE to identify increased liver stiffness in children with CF. With multicenter validation, these data might be used to improve the detection and monitoring of liver fibrosis in children with CF.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Levitte S, Lee LW, Isaacson J, et al. Clinical use of shear-wave elastography for detecting liver fibrosis in children and adolescents with cystic fibrosis. Pediatr Radiol. 2021. PMID: 33759025. doi:10.1007/s00247-021-05015-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。