文献速递腹部泌尿生殖外周血管MR

超氧化铁增强超短TE MRA及肾脏血管定量形态学评估

Ferumoxytol-enhanced ultrashort TE MRA and quantitative morphometry of the human kidney vasculature.
PubMed 文献 · Abdom Radiol (NY) · 2021-03-05

本研究评估超氧化铁增强QUTE-CE MRA用于肾脏腹部血管成像的可行性,4名受试者在3 T下行3D UTE Spiral VIBE WIP序列扫描。QUTE-CE MRA提供动静脉同等明亮的血流快照,最大SNR和CNR分别为3,282±1,218和1,295±580,显著高于其他CEMRA技术的文献值;较标准动态钆增强CEMRA显示更低ISH和更高血管分支级数(第7级 vs 第3级),并可行至第7级分支的定量形态学分析,肾囊肿存在时血管曲率显著增加(p<0.001)。

要点

  • QUTE-CE MRA单次扫描可同时清晰显示肾动脉和静脉,血管分支显示达第7级(钆增强CEMRA为第3级)。
  • 图像质量指标最大SNR 3,282±1,218、最大CNR 1,295±580,高于文献报道的其他CEMRA技术。
  • 肾囊肿邻近血管曲率较正常肾区等效血管显著增加(p<0.001),可用于血管形态定量分析。

关键影像表现/征象

  • QUTE-CE MRA提供明亮血流快照,单次扫描中动脉与静脉显示程度相当。
  • QUTE-CE MRA较标准动态临床钆增强CEMRA显示更低腔内信号异质性(ISH)。
  • QUTE-CE MRA显示肾内血管分支级数达第7级,钆增强CEMRA为第3级。
  • 肾囊肿存在时血管曲率较正常肾区等效血管显著增加(p<0.001)。

诊断标准与关键数值

  • 图像质量指标:最大SNR 3,282±1,218,最大CNR 1,295±580。
  • 血管分支显示级数:QUTE-CE MRA第7级 vs 钆增强CEMRA第3级,QUTE-CE MRA更高。
  • 血管曲率比较:肾囊肿存在时较正常肾区等效血管显著增加,p<0.001。

临床应用与阅片要点

  • QUTE-CE MRA可单次扫描同时评估肾动脉和静脉,并显示至第7级分支的肾内血管。
  • 可利用VMTK半自动方法对腹部及肾内血管行定量形态学分析,包括总肾体积、总囊肿体积及分支动脉直径。
  • 肾囊肿邻近血管曲率增加可作为形态学定量指标。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the feasibility of Quantitative Ultrashort-Time-to-Echo Contrast-Enhanced (QUTE-CE) MRA using ferumoxytol as a contrast agent for abdominal angiography in the kidney.

METHODS: Four subjects underwent ferumoxytol-enhanced MRA with the 3D UTE Spiral VIBE WIP sequence at 3 T. Image quality metrics were quantified, specifically the blood Signal-to-Noise Ratio (SNR), blood-tissue Contrast-to-Noise Ratio (CNR) and Intraluminal Signal Heterogeneity (ISH) from both the aorta and inferior vena cava (IVC). Morphometric analysis of the vessels was performed using manual approach and semi-automatic approach using Vascular Modeling ToolKit (VMTK). Image quality and branching order were compared between QUTE-CE MRA and the Gadolinium (Gd) CEMRA reference image.

RESULTS: QUTE-CE MRA provides a bright blood snapshot that delineates arteries and veins equally in the same scan. The maximum SNR and CNR values were 3,282 ± 1,218 and 1,295 ± 580, respectively - significantly higher than available literature values using other CEMRA techniques. QUTE-CE MRA had lower ISH and depicted higher vessel branching order (7th vs 3rd) within the kidney compared to a standard dynamic clinical Gd CEMRA scan. Morphometric analysis yielded quantitative results for the total kidney volume, total cyst volume and for diameters of the branching arterial network down to the 7th branch. Vessel curvature was significantly increased (p < 0.001) in the presence of a renal cyst compared to equivalent vessels in normal kidney regions.

CONCLUSION: QUTE-CE MRA is feasible for kidney angiography, providing greater detail of kidney vasculature, enabling quantitative morphometric analysis of the abdominal and intra-renal vessels and yielding metrics relevant to vascular diseases while using a contrast agent ferumoxytol that is safe for CKD patients.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Timms L, Zhou T, Lyu Y, et al. Ferumoxytol-enhanced ultrashort TE MRA and quantitative morphometry of the human kidney vasculature. Abdom Radiol (NY). 2021. PMID: 33666735. doi:10.1007/s00261-021-02984-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。