直肠内光声与超声共配准联合深度学习评估直肠癌治疗反应
前瞻性研究纳入32例受试者,采用直肠内共配准光声显微与超声系统联合卷积神经网络评估直肠癌放化疗后反应。光声CNN区分肿瘤与正常组织的AUC为0.98(95%CI: 0.98, 0.99),超声CNN的AUC为0.71(95%CI: 0.70, 0.73)。光声成像可显示完全肿瘤反应者治疗床内正常黏膜下血管架构恢复。
要点
- 光声CNN区分肿瘤与正常组织AUC达0.98,超声CNN仅0.71
- 完全肿瘤反应的光声标志为治疗床内正常黏膜下血管架构恢复
- 系统在测试集5例患者数据上评估,训练验证用22例离体标本和5例在体图像
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Conventional radiologic modalities perform poorly in the radiated rectum and are often unable to differentiate residual cancer from treatment scarring. Purpose To report the development and initial patient study of an imaging system comprising an endorectal coregistered photoacoustic (PA) microscopy (PAM) and US system paired with a convolution neural network (CNN) to assess the rectal cancer treatment response. Materials and Methods In this prospective study (ClinicalTrials.gov identifier NCT04339374), participants completed radiation and chemotherapy from September 2019 to September 2020 and images were obtained with the PAM/US system prior to surgery. Another group's colorectal specimens were studied ex vivo. The PAM/US system consisted of an endorectal imaging probe, a 1064-nm laser, and one US ring transducer. The PAM CNN and US CNN models were trained and validated to distinguish normal from malignant colorectal tissue using ex vivo and in vivo patient data. The PAM CNN and US CNN were then tested using additional in vivo patient data that had not been seen by the CNNs during training and validation. Results Twenty-two patients' ex vivo specimens and five patients' in vivo images (a total of 2693 US regions of interest [ROIs] and 2208 PA ROIs) were used for CNN training and validation. Data from five additional patients were used for testing. A total of 32 participants (mean age, 60 years; range, 35-89 years) were evaluated. Unique PAM imaging markers of the complete tumor response were found, specifically including recovery of normal submucosal vascular architecture within the treated tumor bed. The PAM CNN model captured this recovery process and correctly differentiated these changes from the residual tumor. The imaging system remained highly capable of differentiating tumor from normal tissue, achieving an area under the receiver operating characteristic curve of 0.98 (95% CI: 0.98, 0.99) for data from five participants. By comparison, the US CNN had an area under the receiver operating characteristic curve of 0.71 (95% CI: 0.70, 0.73). Conclusion An endorectal coregistered photoacoustic microscopy/US system paired with a convolutional neural network model showed high diagnostic performance in assessing the rectal cancer treatment response and demonstrated potential for optimizing posttreatment management. © RSNA, 2021 Supplemental material is available for this article. See also the editorial by Klibanov in this issue.
引用
- Leng X, Uddin KMS, Chapman W, et al. Assessing Rectal Cancer Treatment Response Using Coregistered Endorectal Photoacoustic and US Imaging Paired with Deep Learning . Radiology. 2021. PMID: 33754826. doi:10.1148/radiol.2021202208
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。