文献速递腹部CT

多期双能CT碘摄取参数评估肝纤维化

Liver fibrosis assessment with multiphasic dual-energy CT: diagnostic performance of iodine uptake parameters.
PubMed 文献 · Eur Radiol · 2021-03-25

IWR预测纤维化优于ECV,ID法观察者间可重复性更高;IWR与FIB-4联合模型AUC达0.86-0.89。

要点

  • IWR预测肝纤维化AUC 0.76-0.85,优于ECV的0.65-0.73。
  • ID法测ECV和IWR的观察者间ICC高于ΔHU法。
  • IWR与FIB-4联合,ID模型AUC 0.86-0.89。

关键影像表现/征象

  • F≥2、F≥3、F4患者ECV高于对应F≤1、F≤2、F≤3患者,IWR低于对应组(均p<0.001)。

诊断标准与关键数值

  • ECVΔHU预测纤维化严重程度AUC范围0.65-0.71,ECVID为0.67-0.73。
  • IWRΔHU预测纤维化严重程度AUC范围0.76-0.81,IWRID为0.81-0.85。
  • ID法ECV的ICC高于ΔHU法(p=0.045),IWR的ICC亦高于ΔHU法(p<0.001)。
  • IWR和FIB-4为独立预测因子,ΔHU模型联合AUC 0.82-0.87,ID模型联合AUC 0.86-0.89。

临床应用与阅片要点

  • 利用门静脉期和3分钟延迟期碘摄取计算IWR,可辅助预测肝纤维化分期。
  • 双能ID法测量ECV和IWR的观察者间一致性优于常规ΔHU法。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the ability of iodine uptake parameters from hepatic multiphasic CT to predict liver fibrosis, and compare absolute contrast enhancement (ΔHU) with dual-energy iodine density (ID) methods.

METHODS: One hundred seventeen patients with pathologically proven liver fibrosis who underwent dual-energy CT during portal-venous phase (PVP) and 3-min delayed phase (DP) between January 2017 and Octotber 2019 were retrospectively included. Two radiologists measured the hepatic and blood-pool iodine uptake using ΔHU and ID methods; extracellular volume fraction (ECV) and the iodine washout rate (IWR) calculated with both methods were compared between different fibrosis stages (F0-1 vs. F2-4, F0-2 vs. F3-4, or F0-3 vs. F4). The inter-observer reproducibility (intraclass correlation coefficients [ICCs]) for ECV and IWR was compared between the ΔHU and ID methods. The areas under the receiver operating characteristic curves (AUCs) to predict liver fibrosis severity were calculated for serum and imaging fibrosis markers. To identify independent predictors, multivariable logistic regression analysis was performed, and combined performance was assessed for the ΔHU and ID models.

RESULTS: Patients with F ≥ 2 (n = 70), F ≥ 3 (n = 51), and F4 (n = 29) had higher ECV and lower IWR than those with F ≤ 1, F ≤ 2, and F ≤ 3, respectively (all p < 0.001). ICCs were higher in the ID method than in the ΔHU method (ECV: p = 0.045; IWR: p < 0.001). The AUC ranges of ECVΔHU, ECVID, IWRΔHU, and IWRID for predicting liver fibrosis severity were 0.65-0.71, 0.67-0.73, 0.76-0.81, and 0.81-0.85, respectively. IWR and fibrosis-4 index were independent predictors, with combined AUCs of 0.82-0.87 for the ΔHU model and 0.86-0.89 for the ID model.

CONCLUSIONS: IWR more accurately predicted liver fibrosis than ECV in routine multiphasic CT. The dual-energy ID method yielded higher inter-observer reproducibility and predictive values than the single-energy ΔHU method.

KEY POINTS: • The IWR calculated from hepatic iodine uptake during PVP and 3-min DP predicted liver fibrosis (AUC, 0.76-0.85), while the ECV had a relatively limited predictive value (ACU, 0.65-0.73). • Compared with the conventional ΔHU method, the dual-energy ID method provided superior inter-observer reproducibility for measurement of ECV (p = 0.046) and IWR (p < 0.001). • The IWR and FIB-4 served as independent predictors of liver fibrosis; their combination yielded the high diagnostic performance particularly when using the ID method (combined AUCs of 0.86-0.89).

来源:Eur Radiol,查看原文。版权归原作者所有。