文献速递腹部CT

低kVp CT与双能CT评估富血供肝细胞癌的比较

Comparison of low kVp CT and dual-energy CT for the evaluation of hypervascular hepatocellular carcinoma.
PubMed 文献 · Abdom Radiol (NY) · 2021-03-13

回顾性纳入229例肝细胞癌患者,动脉期分别行90 kVp(n=106)或双能扫描(n=123),双能重建为线性融合图及40 keV、50 keV图。双能40 keV图肝癌CNR最高,融合图噪声最低、主观图像质量及整体偏好评分最高;两组辐射剂量无显著差异。

要点

  • 双能40 keV图显示富血供肝癌的CNR最高,有利于病灶检出。
  • 双能线性融合图噪声最低,主观图像质量和整体偏好评分最高。
  • 低kVp与双能扫描的辐射剂量无显著差异。

关键影像表现/征象

  • 双能40 keV图肝癌CNR在四组图像中最高。
  • 双能线性融合图(混合比例0.6,即60% 80 kVp与40% 150 kVp)图像噪声在四组图像中最低。
  • 双能融合图的主观图像质量评分和整体图像偏好评分最高。

诊断标准与关键数值

  • 对比四组图像(90 kVp、双能融合、40 keV、50 keV)的肝癌CNR,双能40 keV最高(p=0.01)。
  • 对比四组图像的噪声,双能融合图最低(p<0.001)。
  • 双能与低kVp扫描的容积CT剂量指数和剂量长度乘积无显著差异(p>0.05)。
  • 主观图像质量和整体偏好评分双能融合图最高(p<0.001)。

临床应用与阅片要点

  • 动脉期评估富血供肝细胞癌时,可参考双能40 keV图提高病灶对比噪声比。
  • 双能线性融合图噪声较低且主观图像质量较高,可作为常规图像参考。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare lesion conspicuity and image quality of arterial phase images obtained from low kVp (90-kVp) and dual-energy (DE) scans for the evaluation of hypervascular hepatocellular carcinoma (HCC).

METHODS: This retrospective study included 229 patients with HCC who underwent either 90 kVp (n = 106) or DE scan (80- and 150-kVp with a tin filter) (n = 123) during the arterial phase. DE scans were reconstructed into a linearly blended image with a mixed ratio of 0.6 (60% 80kVp and 40% 150 kVp) and post-processed for 40 keV and 50 keV images. The contrast-to-noise ratio (CNR) of HCC to the liver and image noise was measured. Lesion conspicuity, liver parenchymal image quality, and overall image preference were assessed qualitatively by three independent radiologists.

RESULTS: DE 40 keV images had the highest CNR of HCC, and DE blended images had the lowest image noise among four image sets (p = 0.01 and p < 0.001, respectively). There was no significant difference in mean volume CT dose index and dose-length product between DE and low kVp scan (ps > 0.05). For qualitative analyses, DE blended images had the highest scores for image quality and overall image preference (ps < 0.001).

CONCLUSION: At an equal radiation dose, DE 40 keV showed higher CNR of HCC and DE blended image showed higher image quality and image preference compared with low kVp CT.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。