自身免疫性胰腺炎的DWI表现:能否作为疾病活动度的影像生物标志物?
结果显示AIP基线ADC显著低于无病胰腺,激素治疗后ADC逐步升高,复发时ADC相对下降但仍高于初发;ADC对疾病活动度的判别优于血清IgG4,但对复发的预测准确性较低。
要点
- AIP基线ADC显著低于无病胰腺,治疗前DWI扩散受限明显。
- 激素治疗后ADC短期、长期随访均逐步升高,可反映治疗反应。
- ADC判别疾病活动度优于血清IgG4,但预测复发准确性较低。
关键影像表现/征象
- AIP基线ADC为0.99±0.12×10⁻³ mm²/s,显著低于无病胰腺的1.26±0.10×10⁻³ mm²/s(p<.001)。
- 激素治疗后ADC短期随访升至1.16±0.12×10⁻³ mm²/s、长期随访升至1.23±0.12×10⁻³ mm²/s(均p<.001)。
- 复发时ADC相对下降至1.11±0.20×10⁻³ mm²/s,但仍显著高于初发(p=.003)。
诊断标准与关键数值
- ADC鉴别基线AIP与临床稳定AIP的AUC为0.867,血清IgG4的AUC为0.700。
- ADC鉴别临床活动AIP与临床稳定AIP的AUC为0.762,血清IgG4的AUC为0.686。
- ADC鉴别复发AIP与临床稳定AIP的AUC为0.648,血清IgG4的AUC为0.669。
临床应用与阅片要点
- 可测量胰腺ADC辅助评估AIP疾病活动度及激素治疗后的动态变化。
- 复发时ADC相对下降但仍高于初发,ADC预测复发准确性较低,判读需结合临床。
- 比较ADC与血清IgG4对活动度的判别时,ADC的AUC更高。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this article was to evaluate the DWI features of autoimmune pancreatitis (AIP) at baseline, under treatment, and at relapse, and to assess the diagnostic accuracy of the ADC for determining disease activity. MATERIALS AND METHODS. This retrospective study was approved by the institutional review board. Sixty-two patients with AIP (48 at initial attack and 14 at relapse) underwent MRI with DWI (b = 0 and 800 s/mm2) at 3 T before receiving corticosteroid therapy (CST) and during follow-up. Seventeen patients had disease relapse during follow-up, whereas the others remained clinically stable. Forty age- and sex-matched patients without pancreatic disease served as the control group. RESULTS. The ADC value of AIP at baseline was significantly lower than that for a disease-free pancreas (0.99 ± 0.12 vs 1.26 ± 0.10 × 10-3 mm2/s, p < .001). Under CST, the ADC value increased gradually at the short-term and long-term follow-up (1.16 ± 0.12 and 1.23 ± 0.12 × 10-3 mm2/s, respectively, both p < .001). At relapse, the ADC had a relative decrease (1.11 ± 0.20 × 10-3 mm2/s) but was significantly higher compared with the initial attack (p = .003). The AUC of ADC serum IgG4 level at ROC analysis for baseline versus clinically stable AIP was 0.867 and 0.700, the AUC for clinically active AIP versus clinically stable AIP was 0.762 and 0.686, and the AUC for relapsed AIP versus clinically stable AIP was 0.648 and 0.669. CONCLUSION. DWI reflected the dynamic change of AIP under CST, and the ADC value for DWI outperformed the serum IgG4 value for determining disease activity. However, relapsed disease showed less diffusion restriction, and the ADC value was less accurate for predicting relapse.
引用
- Zhu L, Zhang W, Jin Z, et al. DWI of Autoimmune Pancreatitis: Is It an Imaging Biomarker for Disease Activity? AJR Am J Roentgenol. 2021. PMID: 33760653. doi:10.2214/AJR.20.23368
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。