文献速递腹部技术与安全CT

晚期结直肠癌放射组学纹理特征与BRAF突变及5年总生存的相关性

Radiomics Texture Features in Advanced Colorectal Cancer: Correlation with BRAF Mutation and 5-year Overall Survival.
PubMed 文献 · Radiol Imaging Cancer · 2020-09-18

该回顾性研究纳入145例IV期结直肠癌患者,从治疗前增强CT提取放射组学纹理特征(均值、标准差、正像素均值MPP、偏度、峰度、熵),在SSF 0、2、4、6下分析其与BRAF突变状态及5年总生存的关系。结果显示BRAF突变肿瘤在SSF 0、4、6下标准差和MPP显著低于野生型;SSF 0偏度≤-0.75和SSF 2均值≥17.76的患者5年OS更好。结论认为纹理特征可能作为BRAF突变状态和5年OS的潜在生物标志物。

要点

  • BRAF突变型肿瘤的纹理标准差和MPP在SSF 0、4、6下显著低于野生型。
  • SSF 0偏度≤-0.75者5年OS更好(HR 0.53,95%CI 0.29-0.94)。
  • SSF 2均值≥17.76者5年OS更好(HR 0.40,95%CI 0.22-0.71)。

关键影像表现/征象

  • 在SSF 0、4、6下,BRAF突变型肿瘤的纹理标准差和MPP显著低于野生型(P分别为.006、.007、.005)。
  • SSF 0偏度≤-0.75和SSF 2均值≥17.76与更好的5年OS相关(log-rank P分别为.025和.002)。
  • 肿瘤部位(右半结肠 vs 左半结肠 vs 直肠)对临床结局无显著影响(log-rank P=.53)。

诊断标准与关键数值

  • SSF 0偏度≤-0.75:5年OS更好,HR 0.53(95%CI 0.29, 0.94),log-rank P=.025。
  • SSF 2均值≥17.76:5年OS更好,HR 0.40(95%CI 0.22, 0.71),log-rank P=.002。
  • BRAF突变型 vs 野生型:SSF 0、4、6下标准差和MPP显著更低(P=.006、.007、.005)。

临床应用与阅片要点

  • 治疗前增强CT提取的纹理特征(标准差、MPP、偏度、均值)可用于辅助判断BRAF突变状态和预后分层。
  • 分析时需记录纹理特征对应的SSF值(0、2、4、6),不同SSF下意义不同。
  • 肿瘤部位(右半 vs 左半 vs 直肠)对5年OS无显著影响,报告中不必据此判断预后。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To explore the potential of radiomics texture features as potential biomarkers to enable detection of the presence of BRAF mutation and prediction of 5-year overall survival (OS) in stage IV colorectal cancer (CRC).

MATERIALS AND METHODS: In this retrospective study, a total of 145 patients (mean age, 61 years ± 14 [standard deviation {SD}]; 68 female patients and 77 male patients) with stage IV CRC who underwent molecular profiling and pretreatment contrast material-enhanced CT scans between 2004 and 2018 were included. Tumor radiomics texture features, including the mean, the SD, the mean value of positive pixels (MPP), skewness, kurtosis, and entropy, were extracted from regions of interest on CT images after applying three Laplacian-of-Gaussian filters known as spatial scaling factors (SSFs) (SSF = 2, fine; SSF = 4, medium; SSF = 6, coarse) by using specialized software; values of these parameters were also obtained without filtration (SSF = 0). The Wilcoxon rank sum test was used to assess differences between mutated versus wild-type BRAF tumors. Associations between radiomics texture features and 5-year OS were determined by using Kaplan-Meier estimators using the log-rank test and multivariate Cox proportional-hazards regression analysis.

RESULTS: The SDs and MPPs of radiomic texture features were significantly lower in BRAF mutant tumors than in wild-type BRAF tumors at SSFs of 0, 4, and 6 (P = .006, P = .007, and P = .005, respectively). Patients with skewness less than or equal to -0.75 at an SSF of 0 and a mean of greater than or equal to 17.76 at an SSF of 2 showed better 5-year OS (hazard ratio [HR], 0.53 [95% confidence interval {CI}: 0.29, 0.94]; HR, 0.40 [95% CI: 0.22, 0.71]; log-rank P = .025 and P = .002, respectively). Tumor location (right colon vs left colon vs rectum) had no significant impact on the clinical outcome (log-rank P = .53).

CONCLUSION: Radiomics texture features can serve as potential biomarkers for determining BRAF mutation status and as predictors of 5-year OS in patients with advanced-stage CRC.Keywords: Abdomen/GI, CT, Comparative Studies, Large BowelSupplemental material is available for this article.© RSNA, 2020.

来源:Radiol Imaging Cancer,查看原文。版权归原作者所有。

引用

  1. Negreros-Osuna AA, Parakh A, Corcoran RB, et al. Radiomics Texture Features in Advanced Colorectal Cancer: Correlation with BRAF Mutation and 5-year Overall Survival. Radiol Imaging Cancer. 2020. PMID: 33778733. doi:10.1148/rycan.2020190084

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。