DWI与MR弹性成像在肝纤维化分期中的诊断性能比较:一项Meta分析
GRE-MRE与SE-EPI-MRE汇总敏感度与特异度均显示高诊断准确率且两者无显著差异;DWI各纤维化分期的汇总ROC曲线下面积(0.83-0.88)显著低于GRE-MRE(0.95-0.97)与SE-EPI-MRE(0.95-0.99)。三种方法均存在显著异质性。
要点
- GRE-MRE与SE-EPI-MRE对各期肝纤维化均高度准确,汇总敏感度与特异度无显著差异。
- DWI各期纤维化汇总AUC为0.83-0.88,显著低于GRE-MRE的0.95-0.97与SE-EPI-MRE的0.95-0.99。
- DWI诊断纤维化仅为中等准确度,但因其广泛可用且易于在常规肝脏MRI中实施,可作为MRE的替代选择。
诊断标准与关键数值
- DWI各纤维化分期的汇总ROC曲线下面积为0.83-0.88。
- GRE-MRE各纤维化分期的汇总ROC曲线下面积为0.95-0.97。
- SE-EPI-MRE各纤维化分期的汇总ROC曲线下面积为0.95-0.99。
- GRE-MRE与SE-EPI-MRE的汇总敏感度和特异度均显示高诊断准确率,且两者间无显著差异。
临床应用与阅片要点
- GRE-MRE与SE-EPI-MRE对各期肝纤维化诊断准确率高,可优先考虑用于肝纤维化分期评估。
- DWI诊断纤维化仅为中等准确度,但因其广泛可用且易于在常规肝脏MRI中实施,可作为MRE的替代选择。
局限性
- 三种影像方法均检测到显著异质性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the diagnostic performance of diffusion-weighted imaging (DWI), gradient-recalled echo-based magnetic resonance elastography (GRE-MRE), and spin-echo echo-planar imaging-based MRE (SE-EPI-MRE) in liver fibrosis staging.
METHODS: A systematic literature search was done to collect studies on the performance of DWI, GRE-MRE, and SE-EPI-MRE for diagnosing liver fibrosis. Pooled sensitivity, specificity, diagnostic odds ratio, positive and negative likelihood ratio, and a summary receiver operating characteristic (ROC) curve were estimated with a bivariate random effects model. Subgroup analyses on various study characteristics were performed.
RESULTS: Sixty studies with a total of 6620 patients were included in the meta-analysis. Pooled sensitivity and specificity of GRE-MRE and SE-EPI-MRE showed high diagnostic accuracy and did not differ significantly. The area under the summary ROC curve for all stages of fibrosis differed significantly between DWI (0.83-0.88) and either GRE-MRE (0.95-0.97) or SE-EPI-MRE (0.95-0.99). Substantial heterogeneity was detected for all three imaging methods.
CONCLUSIONS: Both GRE-MRE and SE-EPI-MRE are highly accurate for detection of each liver fibrosis stage, with high potential to replace liver biopsy. Although DWI had a moderate accuracy in distinguishing liver fibrosis, it could be regarded as an alternative to MRE, since it is widely available and easily implemented in routine liver MRI.
引用
- Jang W, Jo S, Song JS, et al. Comparison of diffusion-weighted imaging and MR elastography in staging liver fibrosis: a meta-analysis. Abdom Radiol (NY). 2021. PMID: 33770223. doi:10.1007/s00261-021-03055-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。