自由呼吸儿童心肌运动校正PSIR延迟强化与单次激发TrueFISP PSIR比较
回顾性纳入238例接受增强心脏磁共振的儿童,均行单次激发TrueFISP PSIR与运动校正(MOCO)PSIR序列,比较SNR、CNR、图像质量评分、LGE范围及伪影。MOCO PSIR的SNR和CNR更高、短轴图像质量评分更优,但扫描时间较单次激发TrueFISP PSIR长;两种序列心肌LGE结果相似且一致性高(ICC=0.955-0.986)。
要点
- 儿童自由呼吸CMRI中,MOCO PSIR较单次激发TrueFISP PSIR获得更高SNR和CNR(p<0.001)。
- MOCO PSIR短轴图像质量评分4(IQR 4-5)优于单次激发TrueFISP PSIR的4(IQR 3-4)(p<0.001)。
- 两种序列心肌LGE范围结果相似,ICC=0.955-0.986,一致性高。
关键影像表现/征象
- MOCO PSIR的SNR和CNR高于单次激发TrueFISP PSIR(p<0.001)。
- 短轴图像质量评分:单次激发TrueFISP PSIR为4(四分位距3-4),MOCO PSIR为4(四分位距4-5)(p<0.001)。
- 单次激发TrueFISP PSIR扫描时间快于MOCO PSIR。
- 两种序列心肌LGE结果相似,一致性高(ICC=0.955-0.986)。
- 原文描述了成像伪影并进行了比较,但摘要未给出具体伪影类型或比较数值。
诊断标准与关键数值
- 图像质量评分采用1-5分制(1=差,5=很好),短轴图像单次激发TrueFISP PSIR为4(IQR 3-4),MOCO PSIR为4(IQR 4-5),p<0.001。
- LGE范围一致性以组内相关系数评价,ICC=0.955-0.986。
- SNR和CNR比较:MOCO PSIR高于单次激发TrueFISP PSIR,p<0.001。
临床应用与阅片要点
- 在自由呼吸儿童CMRI中,MOCO PSIR可提供比单次激发TrueFISP PSIR更高的SNR和CNR,短轴图像质量评分更优。
- MOCO PSIR在高心率下稳健,无需屏气即可完成,适合不能配合屏气的儿童。
- MOCO PSIR扫描时间较单次激发TrueFISP PSIR长。
- 两种序列心肌LGE范围结果相似且一致性高,MOCO PSIR可用于儿童LGE评估。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate the value of motion-corrected (MOCO) phase-sensitive inversion recovery (PSIR) late gadolinium enhancement (LGE) compared with single-shot balanced steady-state gradient echo ("TrueFISP", Siemens) PSIR in free breathing paediatric patients.
MATERIALS AND METHODS: In this retrospective study, 238 paediatric patients underwent clinical contrast-enhanced cardiovascular magnetic resonance imaging (CMRI). Both the single-shot TrueFISP PSIR and MOCO PSIR sequences were performed on each child. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Two radiologists rated the quality of the images on a scale of 1-5 (1 = poor, 5 = very good). Bland-Altman, linear regression, and intraclass correlation coefficient were used to compared the extent of LGE of the single-shot TrueFISP PSIR and MOCO PSIR. Imaging artefacts were described and compared.
RESULTS: Children ranged in age from 60 days to 17 years with an average age of 8.1 ± 3.8 years. MOCO PSIR had higher SNR and CNR than the single-shot TrueFISP PSIR (p<0.001). Mean quality ratings for short-axis imaging were 4 (interquartile range, 3-4) for single-shot TrueFISP PSIR and 4 (interquartile range, 4-5) for MOCO PSIR (p<0.001). The scan time was faster for single-shot TrueFISP PSIR than for MOCO PSIR. The myocardial LGE results were similar with high agreement between the single-shot TrueFISP PSIR and MOCO PSIR (ICC = 0.955-0.986).
CONCLUSION: The MOCO PSIR sequence is feasible in children. MOCO PSIR is robust at high heart rates and can be performed without breath-holding with higher image-quality ratings than the single-shot TrueFISP PSIR.
引用
- Xie LJ, Xu R, Xu ZY, et al. Myocardial motion-corrected phase-sensitive inversion recovery late gadolinium enhancement in free breathing paediatric patients: a comparison with single-shot coherent gradient echo ("TrueFISP") phase-sensitive inversion recovery. Clin Radiol. 2021. PMID: 33663913. doi:10.1016/j.crad.2021.01.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。