光谱CT测定的冠状动脉碘浓度与慢性完全闭塞PCI结局的关系
研究纳入50例慢性完全闭塞(CTO)患者,术前用光谱CT冠状动脉CTA测量近端CTO的碘浓度(CTO-CIC),按分期PCI结局分为成功组与失败组。失败组平均CTO-CIC显著低于成功组(1.3 mg/mL vs 5.2 mg/mL,P < .001),低CTO-CIC(≤ 2.5 mg/mL)预测PCI失败敏感度87%、特异度79%,多变量分析中与PCI失败显著相关(OR 27.0)。
要点
- 术前光谱CT测量CTO近端碘浓度,可辅助预测分期PCI的成败。
- 低CTO-CIC(≤ 2.5 mg/mL)预测PCI失败敏感度87%、特异度79%。
- 多变量分析中低CTO-CIC与PCI失败显著相关(OR 27.0,95%CI 4.9–147.6)。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the feasibility of coronary iodine concentration (CIC) by using spectral CT in the assessment of the outcome of percutaneous coronary intervention (PCI) for chronic total occlusion (CTO).
MATERIALS AND METHODS: In total, 50 consecutive patients underwent preprocedural coronary CT angiography with spectral CT prior to their staged PCI for CTO between June 2017 and July 2018. Iodine density maps, referred to as iodine-no-water maps throughout, with spectral CT provided the CIC at proximal CTO (CTO-CIC). Depending on the outcome of PCI, all CTO lesions were divided into two groups: failed PCI and successful PCI. The receiver operating characteristic curve was used to determine the cutoff values of CTO-CIC in the assessment of the outcome of PCI for CTO.
RESULTS: Of the 50 CTO lesions in 50 patients, 34 (68%) and 16 (32%) were assigned to the successful PCI and failed PCI groups, respectively. The mean CTO-CIC was significantly less in the failed PCI group than in the successful PCI group (1.3 mg/mL ± 0.9 [standard deviation] vs 5.2 mg/mL ± 2.5; P < .001). A low CTO-CIC (≤ 2.5 mg/mL) predicted failed PCI with 87% sensitivity, 79% specificity, 79% positive predictive value, and 90% negative predictive value. At multivariable analysis, the low CTO-CIC was significantly associated with the failed PCI (odds ratio, 27.0; 95% confidence interval: 4.9, 147.6; P < .0001).
CONCLUSION: The CTO-CIC determined by using spectral CT may be useful in the assessment of the outcome of staged PCI for CTO.See also the commentary by Rubinshtein and Blankstein in this issue.© RSNA, 2020.
引用
- Lee JY, Oh YW, Lim DS, et al. Relationship between Coronary Iodine Concentration Determined Using Spectral CT and the Outcome of Percutaneous Coronary Intervention in Patients with Chronic Total Occlusion. Radiol Cardiothorac Imaging. 2020. PMID: 33778600. doi:10.1148/ryct.2020190203
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。