文献速递心血管CT

心脏CT半自动三维混合分割法定量右心室质量:初步研究

Right Ventricular Mass Quantification Using Cardiac CT and a Semiautomatic Three-Dimensional Hybrid Segmentation Approach: A Pilot Study.
PubMed 文献 · Korean J Radiol · 2021-02-02

本研究纳入195例心血管疾病患者,利用心脏CT(270个心动周期)以半自动三维混合分割法定量右心室质量。结果显示96.3%(260/270)数据技术可行,无误差占54.4%、误差≤10%占41.9%、技术失败占3.7%;重复性高(ICC=0.999),收缩末期标化质量显著大于舒张末期(45.9±22.1 g/m² vs. 39.7±20.2 g/m²,p<0.001),且配对值高度相关(r=0.96)。

要点

  • 半自动三维混合分割在96.3%的心脏CT数据中技术可行,仅3.7%失败。
  • 右心室质量定量重复性高(ICC=0.999)。
  • 收缩末期标化质量显著高于舒张末期(45.9 vs 39.7 g/m²)。

关键影像表现/征象

  • 分割误差定义为右心室心肌不连续区域:无误差、≤10%误差、>10%误差(技术失败)。
  • 严重右心室肥厚和收缩末期相位观察到更少误差。

诊断标准与关键数值

  • 技术适用率96.3%(260/270),无误差54.4%(147/270),≤10%误差41.9%(113/270),技术失败3.7%(10/270)。
  • 重复性ICC=0.999(p<0.001)。
  • 标化右心室质量收缩末期45.9±22.1 g/m² vs 舒张末期39.7±20.2 g/m²(p<0.001),配对值相关系数r=0.96(p<0.001)。
  • 严重右心室肥厚组标化质量显著更高(p<0.02),但无肥厚与轻度肥厚组舒张末期数据比较无显著差异(p>0.1)。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the technical applicability of a semiautomatic three-dimensional (3D) hybrid CT segmentation method for the quantification of right ventricular mass in patients with cardiovascular disease.

MATERIALS AND METHODS: Cardiac CT (270 cardiac phases) was used to quantify right ventricular mass using a semiautomatic 3D hybrid segmentation method in 195 patients with cardiovascular disease. Data from 270 cardiac phases were divided into subgroups based on the extent of the segmentation error (no error; ≤ 10% error; > 10% error [technical failure]), defined as discontinuous areas in the right ventricular myocardium. The reproducibility of the right ventricular mass quantification was assessed. In patients with no error or < 10% error, the right ventricular mass was compared and correlated between paired end-systolic and end-diastolic data. The error rate and right ventricular mass were compared based on right ventricular hypertrophy groups.

RESULTS: The quantification of right ventricular mass was technically applicable in 96.3% (260/270) of CT data, with no error in 54.4% (147/270) and ≤ 10% error in 41.9% (113/270) of cases. Technical failure was observed in 3.7% (10/270) of cases. The reproducibility of the quantification was high (intraclass correlation coefficient = 0.999, p < 0.001). The indexed mass was significantly greater at end-systole than at end-diastole (45.9 ± 22.1 g/m² vs. 39.7 ± 20.2 g/m², p < 0.001), and paired values were highly correlated (r = 0.96, p < 0.001). Fewer errors were observed in severe right ventricular hypertrophy and at the end-systolic phase. The indexed right ventricular mass was significantly higher in severe right ventricular hypertrophy (p < 0.02), except in the comparison of the end-diastolic data between no hypertrophy and mild hypertrophy groups (p > 0.1).

CONCLUSION: CT quantification of right ventricular mass using a semiautomatic 3D hybrid segmentation is technically applicable with high reproducibility in most patients with cardiovascular disease.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Goo HW. Right Ventricular Mass Quantification Using Cardiac CT and a Semiautomatic Three-Dimensional Hybrid Segmentation Approach: A Pilot Study. Korean J Radiol. 2021. PMID: 33660457. doi:10.3348/kjr.2020.0787

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。