多模态多参数三维图像融合在冠状动脉疾病中的应用
研究纳入17例同时接受心脏CT和心脏MRI的患者,开发多模态三维图像融合软件,整合CT冠状动脉造影、CT FFR、动态三维心脏MRI灌注和延迟钆增强。图像质量评为良好至优秀,融合信息有助于解决常规二维判读中47%的不确定发现。
要点
- 三维融合将CT FFR色编码与MRI灌注/瘢痕投影至CT高分辨率左心室。
- CT FFR在16/17例(94%)中可行,7/17例(41%)显示异常血流。
- 融合信息解决了8例不确定发现中的6例(75%)。
关键影像表现/征象
- 图像质量评为良好至优秀(评分2.5-2.6,3分为优秀)。
- CT冠状动脉造影显示7/17例(41%)存在显著狭窄。
- CT FFR显示7/17例(41%)异常血流,其中6例与CT冠状动脉造影显著狭窄一致。
- 心脏MRI灌注显示8/17例(47%)低灌注,缺血负荷17%±5。
- 心脏MRI延迟钆增强显示3/17例(18%)心肌瘢痕,瘢痕负荷7%±4。
诊断标准与关键数值
- CT FFR在16/17例(94%)中可行。
- 常规二维判读CT冠状动脉造影和心脏MRI导致8/17例(47%)不确定发现。
- 加入CT FFR和三维图像融合信息后,8例不确定发现中6例(75%)得到解决。
临床应用与阅片要点
- 三维融合可将MRI灌注和延迟钆增强值投影到CT高分辨率左心室,辅助整合功能与解剖信息。
- CT FFR色编码冠状动脉树有助于识别异常血流。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To allow for comprehensive noninvasive diagnostics of coronary artery disease (CAD) by using three-dimensional (3D) image fusion of CT coronary angiography, CT-derived fractional flow reserve (CT FFR), whole-heart dynamic 3D cardiac MRI perfusion, and 3D cardiac MRI late gadolinium enhancement (LGE).
MATERIALS AND METHODS: Seventeen patients (54 years ± 10 [standard deviation], one female) who underwent cardiac CT and cardiac MRI were included (combined subcohort of three prospective trials). Software facilitating multimodal 3D image fusion was developed. Postprocessing of CT data included segmentation of the coronary tree and heart contours, calculation of CT FFR values, and color coding of the coronary tree according to CT FFR. Postprocessing of cardiac MRI data included segmentation of the left ventricle (LV) in cardiac MRI perfusion and cardiac MRI LGE, co-registration of cardiac MRI to CT data, and projection of cardiac MRI perfusion and LGE values onto the high spatial resolution LV from CT.
RESULTS: Image quality was rated as good to excellent (scores: 2.5-2.6; 3 = excellent). CT coronary angiography revealed significant stenoses in seven of 17 cases (41%). CT FFR was possible in 16 of 17 cases (94%) and showed pathologic flow in seven of 17 cases (41%), six of which coincided with cases revealing significant stenoses at CT coronary angiography. Cardiac MRI perfusion identified eight of 17 patients (47%) with hypoperfusion (ischemic burden of 17% ± 5). Cardiac MRI LGE showed myocardial scar in three of 17 cases (18%, scar burden of 7% ± 4). Conventional two-dimensional readout of CT coronary angiography and cardiac MRI resulted in eight of 17 cases (47%) with uncertain findings. Most of these divergent findings could be solved when adding information from CT FFR and 3D image fusion (six of eight, 75%).
CONCLUSION: Multimodal 3D cardiac image fusion is feasible and may help with comprehensive noninvasive CAD diagnostics.Supplemental material is available for this article.© RSNA, 2020.
引用
- von Spiczak J, Mannil M, Model H, et al. Multimodal Multiparametric Three-dimensional Image Fusion in Coronary Artery Disease: Combining the Best of Two Worlds. Radiol Cardiothorac Imaging. 2020. PMID: 33778554. doi:10.1148/ryct.2020190116
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。