基于机器学习的冠脉CT FFR在三联排除CT血管成像急性胸痛中的应用价值
本研究回顾性纳入159例急诊急性胸痛患者,评估基于AI的三联排除CT血管成像衍生的CT FFR。CT FFR≤0.80与狭窄≥50%在52%病例中一致;CT FFR对血运重建和MACE的预测优于狭窄≥50%(OR 3.4 vs 2.2,P<.01)。在有额外心脏检查的亚组中,CT FFR与检查结果的一致率(55%)高于CT血管成像(47%)(P=.23)。
要点
- CT FFR≤0.80对血运重建和MACE的预测优于三联排除CT血管成像狭窄≥50%。
- CT FFR与CT血管成像在CAD严重程度的一致率为52%。
- 有额外心脏检查亚组中CT FFR一致率55%高于CT血管成像47%,但差异无统计学意义。
诊断标准与关键数值
- CT FFR阳性阈值≤0.80;CT血管成像狭窄≥50%为显著狭窄。
- CT FFR与CT血管成像在CAD严重程度的一致率为52%(82/159)。
- CT FFR≤0.80预测血运重建和MACE的OR为3.4(95%CI:1.4,8.2),CT血管成像狭窄≥50%的OR为2.2(95%CI:0.9,5.3),P<.01。
- 有额外无创心脏检查亚组(94/159)中,CT FFR一致率55%,CT血管成像一致率47%,P=.23。
临床应用与阅片要点
- CT FFR可作为三联排除CT血管成像的附加功能学评估,辅助识别急诊急性胸痛中需血运重建的高危患者。
- CT FFR与CT血管成像解剖狭窄仅52%一致,报告时需注意功能学与解剖学不一致的情况。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the additional value of noninvasive artificial intelligence (AI)-based CT-derived fractional flow reserve (CT FFR), derived from triple-rule-out coronary CT angiography for acute chest pain (ACP) in the emergency department (ED) setting.
MATERIALS AND METHODS: AI-based CT FFR from triple-rule-out CT angiography data sets was retrospectively obtained in 159 of 271 eligible patients (102 men; mean age, 57.0 years ± 9.7 [standard deviation]) presenting to the ED with ACP. The agreement between CT FFR (≤ 0.80) and stenosis at triple-rule-out CT angiography (≥ 50%), as well as downstream cardiac diagnostic testing, was investigated. Furthermore, the predictive value of CT FFR for coronary revascularization and major adverse cardiac events (MACE) was assessed over a 1-year follow-up period.
RESULTS: CT FFR and triple-rule-out CT angiography demonstrated agreement in severity of coronary artery disease (CAD) in 52% (82 of 159) of all cases. CT FFR of 0.80 and less served as a better predictor for coronary revascularization and MACE than stenosis of 50% and greater at triple-rule-out CT angiography (odds ratio, 3.4; 95% confidence interval: 1.4, 8.2 vs odds ratio, 2.2; 95% confidence interval: 0.9, 5.3) (P < .01). In the subgroup of patients with additional noninvasive cardiac testing (94 of 159), there was higher agreement as to the presence or absence of significant disease with CT FFR (55%) than with coronary triple-rule-out CT angiography (47%) (P = .23).
CONCLUSION: CT FFR derived from triple-rule-out CT angiography was a better predictor for coronary revascularization and MACE and showed better agreement with additional diagnostic testing than triple-rule-out CT angiography. Therefore, CT FFR may improve the specificity in identifying patients with ACP with significant CAD in the ED setting and reduce unnecessary downstream testing.© RSNA, 2020See also the commentary by Ihdayhid and Ben Zekry in this issue.
引用
- Martin SS, Mastrodicasa D, van Assen M, et al. Value of Machine Learning-based Coronary CT Fractional Flow Reserve Applied to Triple-Rule-Out CT Angiography in Acute Chest Pain. Radiol Cardiothorac Imaging. 2020. PMID: 33778579. doi:10.1148/ryct.2020190137
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。