本研究回顾性纳入30例轻至重度二尖瓣反流患者,比较半自动血流追踪与瓣膜追踪在4D Flow MRI定量二尖瓣反流量的准确性。结果显示血流追踪与间接定量法一致性更好,瓣间一致性更优,观察者间一致性优秀,而瓣膜追踪在重度反流中低估反流量。

要点

  • 血流追踪定量二尖瓣反流量与间接法一致性优于瓣膜追踪,重度反流时更明显。
  • 瓣膜追踪在重度二尖瓣反流中低估反流量,阅片时需注意。
  • 血流追踪观察者间一致性优秀(r=0.95),瓣膜追踪仅为中等(r=0.72)。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the accuracy of semiautomated flow tracking with that of semiautomated valve tracking in the quantification of mitral valve (MV) regurgitation from clinical four-dimensional (4D) flow MRI data obtained in patients with mild, moderate, or severe MV regurgitation.

MATERIALS AND METHODS: The 4D flow MRI data were retrospectively collected from 30 patients (21 men; mean age, 61 years ± 10 [standard deviation]) who underwent 4D flow MRI from 2006 to 2016. Ten patients had mild MV regurgitation, nine had moderate MV regurgitation, and 11 had severe MV regurgitation, as diagnosed by using semiquantitative echocardiography. The regurgitant volume (Rvol) across the MV was obtained using three methods: indirect quantification of Rvol (RvolINDIRECT), semiautomated quantification of Rvol using valve tracking (RvolVALVE), and semiautomated quantification of Rvol using flow tracking (RvolFLOW). A second observer repeated the measurements. Aortic valve flow was quantified as well to test for intervalve consistency. The Wilcoxon signed rank test, orthogonal regression, Bland-Altman analysis, and coefficients of variation were used to assess agreement among measurements and between observers.

RESULTS: RvolFLOW was higher (median, 24.8 mL; interquartile range [IQR], 14.3-45.7 mL) than RvolVALVE (median, 9.9 mL; IQR, 6.0-16.9 mL; P < .001). Both RvolFLOW and RvolVALVE differed significantly from RvolINDIRECT (median, 19.1 mL; IQR, 4.1-47.5 mL; P = .03). RvolFLOW agreed more with RvolINDIRECT (ŷ = 0.78x + 12, r = 0.88) than with RvolVALVE (ŷ = 0.16x + 8.1, r = 0.53). Bland-Altman analysis revealed underestimation of RvolVALVE in severe MV regurgitation. Interobserver agreement was excellent for RvolFLOW (r = 0.95, coefficient of variation = 27%) and moderate for RvolVALVE (r = 0.72, coefficient of variation = 57%). Orthogonal regression demonstrated better intervalve consistency for flow tracking (ŷ = 1.2x - 13.4, r = 0.82) than for valve tracking (ŷ = 2.7x - 92.4, r = 0.67).

CONCLUSION: Flow tracking enables more accurate 4D flow MRI-derived MV regurgitation quantification than valve tracking in terms of agreement with indirect quantification and intervalve consistency, particularly in severe MV regurgitation.Supplemental material is available for this article.© RSNA, 2020.