1.5T冠状动脉MR血管成像应用硝酸甘油:冠状动脉血管扩张的诊断效能
这项前瞻性研究纳入70例疑似冠心病患者,57例完成硝酸甘油前后冠状动脉MR血管成像。应用硝酸甘油后诊断效能显著提高(P < .001),但显著冠心病组的硝酸甘油诱导冠状动脉血管扩张程度低于非显著冠心病组。
要点
- 硝酸甘油可显著提高冠状动脉MR血管成像诊断显著冠心病的效能(P < .001)。
- 应用硝酸甘油后特异性从25.0%升至62.5%,准确率从77.2%升至87.7%。
- 显著冠心病患者的硝酸甘油诱导冠状动脉血管扩张程度显著低于非显著冠心病组。
关键影像表现/征象
- 硝酸甘油诱导的冠状动脉血管扩张在显著冠心病组显著低于非显著冠心病组。
诊断标准与关键数值
- 以X线冠状动脉造影狭窄≥50%定义显著冠状动脉狭窄。
- 患者水平硝酸甘油前 vs 后:敏感度97.6%(95%CI 85.6%, 99.9%) vs 97.6%(95%CI 85.6%, 99.9%)。
- 患者水平硝酸甘油前 vs 后:特异度25.0%(95%CI 8.3%, 52.5%) vs 62.5%(95%CI 35.9%, 83.7%)。
- 患者水平硝酸甘油前 vs 后:阳性预测值76.9%(95%CI 62.8%, 87.0%) vs 87.0%(95%CI 73.0%, 94.6%)。
- 患者水平硝酸甘油前 vs 后:阴性预测值80.0%(95%CI 29.9%, 98.9%) vs 90.9%(95%CI 57.1%, 99.5%);准确率77.2%(95%CI 66.3%, 88.1%) vs 87.7%(95%CI 79.2%, 96.3%)。
临床应用与阅片要点
- 冠状动脉MR血管成像应用硝酸甘油后可提高诊断显著冠心病的特异性、阳性预测值、阴性预测值和准确率。
- 阅片时注意显著冠心病患者的硝酸甘油诱导冠状动脉血管扩张可能受损。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the influence of applying nitroglycerin (NTG) on detecting significant coronary artery disease (CAD) and NTG-induced coronary vasodilation using coronary MR angiography in patients suspected of having CAD.
MATERIALS AND METHODS: In this prospective study conducted from November 2017 to September 2018, 70 consecutive participants suspected of having CAD were recruited. Of those, 57 patients successfully underwent pre- and post-NTG coronary MR angiography, both of which were performed during the end-systolic phase of the cardiac cycle. Significant coronary stenosis was defined at x-ray coronary angiography as stenosis of 50% or more. Participants were divided into a significant CAD group (significant stenosis) and nonsignificant CAD group (no significant stenosis) based on x-ray coronary angiography. Paired and unpaired Student t, generalized linear mixed model, and McNemar tests were used.
RESULTS: The diagnostic performance of coronary MR angiography was significantly improved after NTG (P < .001). Per-patient for coronary MR angiography, from before to after NTG, respectively, the sensitivity was 97.6% (95% confidence interval [CI]: 85.6%, 99.9%) to 97.6% (95% CI: 85.6%, 99.9%), specificity was 25.0% (95% CI: 8.3%, 52.5%) to 62.5% (95% CI: 35.9%, 83.7%), positive predictive value was 76.9% (95% CI: 62.8%, 87.0%) to 87.0% (95% CI: 73.0%, 94.6%), negative predictive value was 80.0% (95% CI: 29.9%, 98.9%) to 90.9% (95% CI: 57.1%, 99.5%), and accuracy was 77.2% (95% CI: 66.3%, 88.1%) to 87.7% (95% CI: 79.2%, 96.3%). The NTG-induced coronary vasodilation was significantly lower in the significant CAD group compared with the nonsignificant CAD group.
CONCLUSION: Administration of NTG significantly improved the diagnostic performance of coronary MR angiography for detecting significant CAD; however, NTG-induced coronary vasodilation was impaired in patients with significant CAD.© RSNA, 2020See also commentary by François in this issue.
引用
- Zhao SH, Li CG, Chen YY, et al. Applying Nitroglycerin at Coronary MR Angiography at 1.5 T: Diagnostic Performance of Coronary Vasodilation in Patients with Coronary Artery Disease. Radiol Cardiothorac Imaging. 2020. PMID: 33778548. doi:10.1148/ryct.2020190018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。