多中心临床试验中MRI主动脉僵硬度测量的变异性:脉搏波速度与主动脉应变测量的观察者内、观察者间及扫描间变异性
结果显示主动脉应变变异性在远端降主动脉最低(观察者内、观察者间、扫描间中位COV分别为1.6%、4.0%、10.3%),在升主动脉最高(分别为3.6%、10.7%、19.8%);PWV变异性低(分别为0.7%、1.5%、8.1%)。结论认为标准化MRI方案下多中心试验中主动脉应变和PWV测量可实现低变异性。
要点
- 主动脉应变测量在远端降主动脉变异性最低(扫描间COV 10.3%),升主动脉最高(扫描间COV 19.8%)。
- PWV测量变异性低(观察者内COV 0.7%,观察者间1.5%,扫描间8.1%)。
- 标准化3-T MRI方案下多中心试验中主动脉应变和PWV测量变异性可接受。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess intraobserver, interobserver, and scan-rescan variability of MRI aortic stiffness measurements in a multicenter trial setting.
MATERIALS AND METHODS: This study was a retrospective analysis of prospectively collected data in a multicenter prospective clinical trial (clinicaltrials.gov ID NCT01870739). Forty-five adult patients (31 men; mean age, 58 years ± 12 [standard deviation]; 15 patients per center; three centers) with arterial hypertension underwent standardized 3-T baseline MRI assessments between June and September 2014. Aortic strain was calculated from maximum and minimum aortic area measurements repeated three times by three readers at three aortic levels on three retrospectively gated axial gradient-echo (GRE) data sets. Pulse wave velocity (PWV) was assessed three times by five readers as Δx/Δt: Δx was measured on a parasagittal GRE image of the aortic arch, and Δt was extracted from ascending and descending aortic velocity curves created on three axial phase-contrast acquisitions. Intraobserver, interobserver, and scan-rescan variability was calculated using percentage coefficient of variation (COV).
RESULTS: Aortic strain variability was lowest at the level of the distal descending aorta (DDA) with median COVs of 1.6% for intraobserver variability, 4.0% for interobserver variability, and 10.3% for scan-rescan variability. It was highest at the ascending aorta (AA) with COVs of 3.6% for intraobserver variability, 10.7% for interobserver variability, and 19.8% for scan-rescan variability. Variability of PWV was low: 0.7% for intraobserver variability, 1.5% for interobserver variability, and 8.1% for scan-rescan variability.
CONCLUSION: Low variability can be achieved for aortic strain and PWV measurements in a multicenter trial setting using standardized MRI protocols. Although COV was lower when measuring aortic strain at DDA compared with AA, variability was acceptable at both anatomic locations.Supplemental material is available for this article.© RSNA, 2020.
引用
- Hrabak-Paar M, Kircher A, Al Sayari S, et al. Variability of MRI Aortic Stiffness Measurements in a Multicenter Clinical Trial Setting: Intraobserver, Interobserver, and Intracenter Variability of Pulse Wave Velocity and Aortic Strain Measurement. Radiol Cardiothorac Imaging. 2020. PMID: 33778551. doi:10.1148/ryct.2020190090