文献速递心血管CT

CT在重度主动脉瓣狭窄患者二叶式主动脉瓣诊断与分型中的附加价值

Additive Value of CT to Age, Aortic Diameter, and Echocardiography in Diagnosis and Classification of Bicuspid Aortic Valve in Patients with Severe Aortic Stenosis.
PubMed 文献 · Radiol Cardiothorac Imaging · 2021-02-04

回顾性纳入212例重度主动脉瓣狭窄患者,开发并验证CT诊断算法用于二叶式主动脉瓣(BAV)诊断与分型,并与外科诊断对照。CT与外科诊断一致性优秀(BAV检出κ=0.90)或良好(分型κ=0.69);在年龄、主动脉直径指数和TTE基础上加入CT可提高AUC(0.97 vs 0.91)和NRI(1.79)。

要点

  • CT诊断BAV与外科诊断一致性优秀(κ=0.90),分型一致性良好(κ=0.69)。
  • 在年龄、主动脉直径指数和TTE基础上加CT,AUC由0.91升至0.97。

核心结论

  • CT诊断与外科诊断一致,且在传统诊断方法基础上具有附加价值。
  • 但CT诊断为功能性BAV的患者存在漏诊先天性BAV的风险。

研究设计与样本

  • 回顾性研究,纳入2012至2017年212例重度主动脉瓣狭窄并接受CT后行主动脉瓣置换术的连续患者。
  • 平均年龄71岁(范围27-93岁),女性125例,37%为BAV。
  • 以外科诊断为参考标准,评估CT诊断算法的重复性和一致性。
  • 采用AUC、NRI和决策曲线分析评估CT在年龄、主动脉直径指数和TTE基础上的附加价值。

诊断标准与关键数值

  • CT与外科诊断BAV检出的一致性κ=0.90,BAV分型的一致性κ=0.69。
  • CT诊断的观察者内和观察者间重复性良好或优秀(所有κ≥0.6)。

临床应用与阅片要点

  • CT诊断算法可用于BAV诊断与分型,与外科诊断一致性良好。
  • 在年龄、主动脉直径指数和TTE基础上加入CT可提高诊断效能(AUC 0.97 vs 0.91)。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To develop and validate a CT diagnostic algorithm for bicuspid aortic valve (BAV) classification.

MATERIALS AND METHODS: This retrospective study included 212 consecutive patients with severe aortic stenosis who underwent CT followed by aortic valve replacement (mean age, 71 years [range, 27-93 years]; 125 women; 37% with a BAV) from 2012 to 2017. BAV diagnosis and BAV category were determined by using the CT diagnostic algorithm developed and were compared with those attained through surgical diagnosis. Reproducibility and agreement were assessed using the Cohen kappa (κ) coefficient. The value of adding CT to age, aortic diameter index, and transthoracic echocardiography (TTE) was evaluated by using the area under the receiver operating characteristic curve (AUC), net reclassification improvement (NRI), and decision-curve analysis.

RESULTS: Intra- and interobserver reproducibility were good or excellent for all CT diagnoses (κ ≥ 0.6 for all). Agreement between CT and surgical diagnoses was excellent (κ = 0.90) for BAV detection and good (κ = 0.69) for BAV categorization. Sixteen percent (five of 31) of patients with functional BAV diagnosed by using CT received a diagnosis of congenital BAV at surgery. The addition of CT to age, aortic diameter, and TTE showed a higher AUC (with CT, 0.97 [95% CI: 0.91, 0.99] vs without CT, 0.91 [95% CI: 0.85, 0.95]; P = .003) and NRI (1.79 [95% CI: 1.65, 1.92], P < .001) and a higher net benefit among all BAV probabilities.

CONCLUSION: CT diagnosis was consistent with surgical diagnosis and had an additive value over traditional diagnostic methods; however, there was a risk of overlooking congenital BAV in patients with functional BAV diagnosed by using CT.Supplemental material is available for this article.© RSNA, 2021.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Takagi H, Yoshizawa M, Orii M, et al. Additive Value of CT to Age, Aortic Diameter, and Echocardiography in Diagnosis and Classification of Bicuspid Aortic Valve in Patients with Severe Aortic Stenosis. Radiol Cardiothorac Imaging. 2021. PMID: 33778656. doi:10.1148/ryct.2021200423

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。