文献速递心血管PETMR

13N-氨水混合PET/MRI在血管扩张负荷下同步评估冠状动脉血流储备与左心室功能

Simultaneous assessment of coronary flow reserve and left ventricular function during vasodilator stress evaluated by 13N-ammonia hybrid PET/MRI.
PubMed 文献 · Clin Radiol · 2021-03-19

研究纳入52例疑似冠心病患者,在腺苷负荷下用13N-氨水混合PET/MRI同步评估心肌血流量、冠状动脉血流储备(CFR)与左心室功能。结果显示所有患者及CFR<2、负荷MBF<1.3 ml/g/min、灌注异常、多支病变亚组的左室容积和LVEF在负荷下均无变化;仅4例LVEF下降>5%,其CFR更低、病变血管数更多。

要点

  • 腺苷负荷下左室容积与LVEF在多数疑似冠心病患者中保持不变。
  • 负荷下LVEF下降>5%仅见于4例,提示可能与严重CAD相关。
  • LVEF下降者CFR更低(1.57±0.12 vs 2.18±0.86,p<0.01)。

关键影像表现/征象

  • 负荷下左室舒张末期容积、收缩末期容积和LVEF在所有患者(n=52)中均保持不变。
  • 在CFR<2(n=27)、负荷MBF<1.3 ml/g/min(n=28)、心肌灌注异常(n=30)及多于一支病变血管(n=46)的患者中,左室容积和LVEF亦保持不变。
  • 仅4例患者负荷下MRI测得LVEF下降>5%。

诊断标准与关键数值

  • 心肌灌注异常定义为 summed difference score ≥4。
  • CFR<2、负荷MBF<1.3 ml/g/min 为原文所用分组条件。
  • 负荷下LVEF下降>5%者CFR为1.57±0.12,无负荷后左室功能障碍者为2.18±0.86(p<0.01)。
  • 负荷下LVEF下降>5%者病变血管数为2.75±0.50,无负荷后左室功能障碍者为1.48±0.92(p<0.01)。

临床应用与阅片要点

  • 腺苷负荷下左室容积与LVEF通常稳定,阅片时不应仅凭负荷下LVEF无变化排除严重CAD。
  • 若负荷下LVEF下降>5%,应结合CFR和病变血管数评估,提示可能存在严重CAD。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To explore changes in left ventricular (LV) function and the relationship of these changes with myocardial blood flow (MBF) evaluated by 13N-ammonia hybrid positron-emission tomography (PET)/magnetic resonance imaging (MRI) during vasodilator stress in patients with suspected coronary artery disease (CAD).

MATERIALS AND METHODS: Fifty-two consecutive patients with suspected CAD, who underwent 13N-ammonia PET/MRI, were enrolled. Vasodilator stress was induced by intravenous injection of adenosine. MBF and coronary flow reserve (CFR) were calculated from dynamic acquisition of 13N-ammonia PET. LV function was evaluated by MRI both at rest and during vasodilator stress. An abnormal perfusion on myocardial images was defined as a summed difference score of ≥4.

RESULTS: MRI showed that the LV end-diastolic volume, LV end-systolic volume, and LV ejection fraction (LVEF) remained unchanged during vasodilator stress in all patients (n=52) as well as in the patients with CFR of <2 (n=27), stress MBF of <1.3 ml/g/min (n=28), abnormal myocardial perfusion (n=30), and more than one diseased vessel (n=46). In only four patients, the LVEF measured by MRI decreased by >5% during vasodilator stress. In these four patients, CFR was lower (1.57 ± 0.12 versus 2.18 ± 0.86, p<0.01) and the number of diseased vessels was higher (2.75 ± 0.50 versus 1.48 ± 0.92, p<0.01) than in patients without post-stress LV dysfunction.

CONCLUSION: The LV volume and systolic function evaluated by cardiac MRI remained unchanged during vasodilator stress; however, LV dysfunction during vasodilator stress may occur in patients with severe CAD.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Kiko T, Yokokawa T, Masuda A, et al. Simultaneous assessment of coronary flow reserve and left ventricular function during vasodilator stress evaluated by 13N-ammonia hybrid PET/MRI. Clin Radiol. 2021. PMID: 33752883. doi:10.1016/j.crad.2021.02.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。