CT测量主动脉根部的线性尺寸、面积及与超声心动图的比较
回顾性分析70例三叶主动脉瓣患者的TTE与心电门控CT,在冠状面、短轴面和三腔面测量9个线性径线。CT短轴测量可重复性极佳(ICC 0.96-0.99),与主动脉根面积相关性好(R 0.97)。CT冠状面和短轴最大径较TTE系统性大约2 mm,而交界至交界测量较TTE小约2 mm,提示需注明测量平面。
要点
- CT短轴测量主动脉根部可重复性最佳(ICC 0.96-0.99),冠状面和三腔面较低。
- CT冠状面和短轴最大径较TTE系统性大约2 mm,交界间径较TTE小约2 mm。
- 报告应注明CT测量平面和具体线性径线,避免随访比较歧义。
诊断标准与关键数值
- CT短轴测量主动脉根部ICC 0.96-0.99,冠状面ICC 0.90(95%CI 0.84-0.94),三腔面ICC 0.92(95%CI 0.87-0.95)。
- CT冠状面和短轴最大径较TTE平均大2 mm(p < 0.001)。
- CT右冠瓣至交界(RCC-comm)平均值较TTE小2 mm(p < 0.001)。
- 所有CT短轴测量与主动脉根面积相关性好,短轴最大径Pearson R 0.97。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: We sought to assess the different CT aortic root measurements and determine their relationship to transthoracic echocardiography (TTE).
METHODS: TTE and ECG-gated CT images were reviewed from 70 consecutive patients (mean age 54 ± 18 years; 67% male) with tricuspid aortic roots (trileaflet aortic valves) between Nov 2009 and Dec 2013. Three CT planes (coronal, short axis en face and three-chamber) were used for measurement of nine linear dimensions. TTE aortic root dimension was measured as per guidelines from the parasternal long axis view.
RESULTS: All CT short axis measurements of the aortic root had excellent reproducibility (intraclass correlation coefficient, ICC 0.96-0.99), while coronal and three-chamber planes had lower reproducibility with ICC 0.90 (95% CI 0.84-0.94) and ICC 0.92 (0.87-0.95) respectively. CT coronal and short axis maximal dimensions were systematically larger than TTE (mean 2 mm larger, p < 0.001), while CT cusp to commissure measurements were systematically smaller (CT RCC-comm mean 2 mm smaller than TTE, p < 0.001). All CT short axis measurements had excellent correlation with aortic root area with CT short axis maximal dimension marginally better than the rest (Pearson's R 0.97).
CONCLUSION: Systematic differences exist between CT and TTE dependent on the CT plane of measurement. All CT short axis measurements of the aortic root had excellent reproducibility and correlation with aortic root area with maximal dimension appearing marginally better than the rest. Our findings highlight the importance of specifying the chosen plane of aortic root measurement on CT.
ADVANCES IN KNOWLEDGE: Systematic differences in aortic root dimension exist between TTE and the various CT measurement planes. CT coronal and short axis maximal dimensions were systematically larger than TTE, while CT cusp to commissure measurements were smaller. CT readers should indicate the plane of measurement and the specific linear dimension to avoid ambiguity in follow-up and comparison.
引用
- Leong K, Knipe H, Binny S, et al. Aortic root measurement on CT: linear dimensions, aortic root area and comparison with echocardiography. A retrospective cross sectional study. Br J Radiol. 2021. PMID: 33684302. doi:10.1259/bjr.20201232