文献速递外周血管心血管CT

基于机器学习的B型主动脉夹层CT真腔与假腔分割

CT-based True- and False-Lumen Segmentation in Type B Aortic Dissection Using Machine Learning.
PubMed 文献 · Radiol Cardiothorac Imaging · 2020-06-25

研究开发了包含两个卷积神经网络的分割流程,在垂直于主动脉中心线的多平面重建上分割B型主动脉夹层CT血管造影的真腔与假腔,并衍生主动脉直径及真假腔横截面积等形态学特征。测试集真腔平均DSC为0.873±0.056、假腔为0.894±0.040,自动最大直径测量与手动测量相关性好(R²=0.95)。

要点

  • 自动分割流程可在垂直于主动脉中心线的MPR上识别真腔与假腔。
  • 测试集真腔DSC 0.873±0.056、假腔DSC 0.894±0.040。
  • 自动最大直径与手动测量高度相关(R²=0.95)。

关键影像表现/征象

  • 分割流程在垂直于主动脉中心线的多平面重建上分割真腔与假腔。
  • 测试集真腔平均DSC为0.873±0.056,假腔平均DSC为0.894±0.040。
  • 自动最大直径测量与手动测量相关性好(R²=0.95)。
  • 可衍生多次随访的横截面直径、真腔面积和假腔面积曲线。

诊断标准与关键数值

  • 分割准确性以Dice相似系数(DSC)评价,测试集真腔0.873±0.056、假腔0.894±0.040。
  • 自动最大直径与手动测量相关性R²=0.95。

临床应用与阅片要点

  • 自动分割可在垂直于主动脉中心线的MPR上获得真腔与假腔的横截面积及直径,供监测与危险分层参考。
  • 自动最大直径测量与手动测量相关性好(R²=0.95),可作为定量随访的辅助手段。
  • 分割结果可生成多次随访的横截面直径、真腔面积和假腔面积曲线。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To develop a segmentation pipeline for segmentation of aortic dissection CT angiograms into true and false lumina on multiplanar reformations (MPRs) perpendicular to the aortic centerline and derive quantitative morphologic features, specifically aortic diameter and true- or false-lumen cross-sectional area.

MATERIALS AND METHODS: An automated segmentation pipeline including two convolutional neural network (CNN) segmentation algorithms was developed. The algorithm derives the aortic centerline, generates MPRs orthogonal to the centerline, and segments the true and false lumina. A total of 153 CT angiograms obtained from 45 retrospectively identified patients (mean age, 50 years; range, 22-79 years) were used to train (n = 103), validate (n = 22), and test (n = 28) the CNN pipeline. Accuracy was evaluated by using the Dice similarity coefficient (DSC). Segmentations were then used to derive the maximal diameter of test-set patients and cross-sectional area profiles of the true and false lumina.

RESULTS: The segmentation pipeline yielded a mean DSC of 0.873 ± 0.056 for the true lumina and 0.894 ± 0.040 for the false lumina of test-set cases. Automated maximal diameter measurements correlated well with manual measurements (R 2 = 0.95). Profiles of cross-sectional diameter, true-lumen area, and false-lumen area over several follow-up examinations were derived.

CONCLUSION: A segmentation pipeline was used to accurately identify true and false lumina on CT angiograms of aortic dissection. These segmentations can be used to obtain diameter and other morphologic parameters for surveillance and risk stratification.Supplemental material is available for this article.© RSNA, 2020.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Hahn LD, Mistelbauer G, Higashigaito K, et al. CT-based True- and False-Lumen Segmentation in Type B Aortic Dissection Using Machine Learning. Radiol Cardiothorac Imaging. 2020. PMID: 33778582. doi:10.1148/ryct.2020190179

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。