文献速递胸部腹部技术与安全CT

全身视野光子计数探测器CT临床应用的首次体验

Computed tomography with a full FOV photon-counting detector in a clinical setting, the first experience.
PubMed 文献 · Eur J Radiol · 2021-02-24

本研究评估了集成光子计数探测器CT(PC-CT)在临床患者体部成像中的可行性,共纳入120例检查,分为标准剂量肺、低剂量肺、超高分辨率肺、标准剂量腹部、低剂量腹部及超高分辨率腹部CTA六组。结果显示PC-CT在超高分辨率模式下辐射剂量显著低于能量积分CT(p<0.0001),标准剂量组剂量相当,且肺及腹部成像的实质信号与背景噪声比显著更高(p<0.0001)。结论认为PC-CT成像稳定、诊断质量优异,在相当或更优剂量下信号与分辨率优势明显。

要点

  • PC-CT在超高分辨率模式下辐射剂量显著低于能量积分CT(p<0.0001)。
  • PC-CT肺及腹部成像的实质信号与背景噪声比显著更高(p<0.0001)。
  • 标准剂量PC-CT的辐射剂量与能量积分CT相当。

关键影像表现/征象

  • PC-CT在肺及腹部成像中实质信号与背景噪声比均显著高于能量积分CT(p<0.0001)。
  • PC-CT在超高分辨率模式下辐射剂量显著低于能量积分CT(p<0.0001)。
  • 标准剂量PC-CT检查的辐射剂量与能量积分CT相当。

临床应用与阅片要点

  • PC-CT可用于临床体部成像,在超高分辨率模式下可在显著降低辐射剂量的同时保持诊断质量。
  • PC-CT在肺及腹部成像中提供更高的实质信号与背景噪声比,可能有助于提升图像判读信心。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: to assess the feasibility of CT with an integrated photon-counting-detector system (PC-CT) in the body imaging of clinical patients.

METHODS: 120 examinations using photon counting detector CT were evaluated in six groups: 1/ a standard-dose lung, 2/ low-dose lung, 3/ ultra-high resolution (UHR) lung, 4/ standard-dose abdominal, 5/ lower-dose abdominal, 6/ UHR abdominal CTA. All CT examinations were performed on a single-source prototype device equipped with a photon counting detector covering a 50 cm scan field of view. Standard dose examinations were performed with the use of detector element size of 0.4 mm, ultra-high-resolution examinations with the detector element size of 0.2 mm, respectively. The stability of the system during imaging was tested. The diagnostic quality of the acquired images was assessed based on the imaging of key structures and the noise level in five-point scale, the effective dose equivalent, dose length product and noise level, and also relation to body mass index and body surface area were compared with three similar groups of CT images made with energy integrating high end scanner. The parameters were evaluated using Wilcoxon test for independent samples, the independence was tested using Kruskal-Wallis test.

RESULTS: When PC-CT images radiation dose is compared with the similar imaging using energy integrating CT, the PC-CT shows lower dose in ultra-high resolution mode, the dose is significantly lower (p < 0.0001), the standard dose examinations were performed with the comparable radiation doses. PC-CT exhibited the significantly higher ratio between parenchyma signal and background noise both in lung and in abdominal imaging (p < 0.0001).

CONCLUSIONS: PC-CT showed imaging stability and excellent diagnostic quality at dose values that are comparable or better to the quality of energy integrating CT, the better signal and improved resolution is most important advantage of photon counting detector CT over energy integrating detector CT.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ferda J, Vendiš T, Flohr T, et al. Computed tomography with a full FOV photon-counting detector in a clinical setting, the first experience. Eur J Radiol. 2021. PMID: 33657475. doi:10.1016/j.ejrad.2021.109614

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。