亚实性结节富集肺癌筛查CT中Lung-RADS分类的观察者间变异
回顾性分析2013-2017年低剂量筛查CT报告,纳入54例含亚实性结节基线CT及108例阴性CT,共162例由两名胸部放射科医师共识分类Lung-RADS,并随机抽取60例由5名放射科医师独立分类。平均60.3%病例和45.0%阳性筛查被正确分类,总体观察者间一致性为中等(平均κ 0.45;95%CI 0.40-0.51),经验丰富的胸部放射科医师一致性显著更高。
要点
- Lung-RADS分类总体观察者间一致性为中等(平均κ 0.45;95%CI 0.40-0.51)。
- 总体仅60.3%病例和45.0%阳性筛查被正确分类,主要不一致率27.3%。
- 经验丰富的胸部放射科医师分类准确性和一致性显著高于住院医师。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess interobserver agreement in Lung CT Screening Reporting and Data System (Lung-RADS) categorisation in subsolid nodule-enriched low-dose screening CTs.
METHODS: A retrospective review of low-dose screening CT reports from 2013 to 2017 using keyword searches for subsolid nodules identified 54 baseline CT scans. With an additional 108 negative screening CT scans, a total of 162 CT scans were categorised according to the Lung-RADS by two fellowship-trained thoracic radiologists in consensus. We randomly selected 20, 20, 10, and 10 scans from categories 1/2, 3, 4A, and 4B CT scans, respectively, to ensure balanced category representation. Five radiologists classified the 60 CT scans into Lung-RADS categories. The frequencies of concordance and minor and major discordance were calculated, with major discordance defined as at least 6 months of management discrepancy. We used Cohen's κ statistics to analyse reader agreement.
RESULTS: An average of 60.3% (181 of 300) of all cases and 45.0% (90 of 200) of positive screens were correctly categorised. The minor and major discordance rates were 12.3% and 27.3% overall and 18.5% and 36.5% in positive screens, respectively. The concordance rate was significantly higher among experienced thoracic radiologists. Overall, the interobserver agreement was moderate (mean κ, 0.45; 95% confidence interval: 0.40-0.51). The proportion of part-solid risk-dominant nodules was significantly higher in cases with low rates of accurate categorisation.
CONCLUSION: This retrospective study observed variable accuracy and moderate interobserver agreement in radiologist categorisation of subsolid nodules in screening CTs. This inconsistency may affect management recommendations for lung cancer screening.
KEY POINTS: • Diagnostic performance for Lung-RADS categorisation is variable among radiologists with fair to moderate interobserver agreement in subsolid nodule-enriched CT scans. • Experienced thoracic radiologists showed more accurate and consistent Lung-RADS categorisation than radiology residents. • The relative abundance of part-solid nodules was a potential factor related to increased disagreement in Lung-RADS categorisation.
引用
- Yoon SH, Kim YJ, Doh K, et al. Interobserver variability in Lung CT Screening Reporting and Data System categorisation in subsolid nodule-enriched lung cancer screening CTs. Eur Radiol. 2021. PMID: 33733688. doi:10.1007/s00330-021-07800-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。