文献速递胸部心血管骨肌CT

AI平台在非增强胸部CT评估中与临床放射学报告的对比表现

Performance of an Artificial Intelligence-Based Platform Against Clinical Radiology Reports for the Evaluation of Noncontrast Chest CT.
PubMed 文献 · Acad Radiol · 2021-03-10

该回顾性研究连续纳入100例非增强胸部CT患者,以两位放射科医师共识读片为参考,比较AI平台与临床报告对肺部病变、肺气肿、主动脉扩张、冠状动脉钙化(CAC)和椎体压缩骨折(VCF)的诊断表现。AI在识别主动脉扩张和CAC上优于报告,而报告在识别肺部病变和VCF上优于AI,肺气肿两者表现相当。结论提示将AI支持平台纳入放射学工作流程可为临床报告提供显著附加价值。

要点

  • AI在主动脉扩张和CAC的检出上敏感度显著高于临床报告,但主动脉扩张特异度低于报告。
  • 临床报告对肺部病变和VCF的敏感度与特异度均高,AI对VCF特异度仅63.7%。
  • 肺气肿的AI与报告诊断表现无显著差异(p=0.064),AI敏感度80.6%、特异度66.7%。

诊断标准与关键数值

  • 主动脉扩张:AI敏感度96.3%、特异度81.4%、AUC 0.89,报告敏感度25.9%、特异度100%、AUC 0.63,p<0.001,AI优于报告。
  • 冠状动脉钙化(CAC):AI敏感度89.8%、特异度100%、AUC 0.95,报告敏感度75.4%、特异度94.9%、AUC 0.85,p=0.005,AI优于报告。
  • 肺部病变:报告敏感度97.6%、特异度100%、AUC 0.99,AI敏感度92.8%、特异度82.4%、AUC 0.88,p=0.024,报告优于AI。
  • 椎体压缩骨折(VCF):报告敏感度100%、特异度100%、AUC 1.0,AI敏感度100%、特异度63.7%、AUC 0.82,p<0.001,报告优于AI。
  • 肺气肿:AI敏感度80.6%、特异度66.7%、AUC 0.74,报告敏感度74.2%、特异度97.1%、AUC 0.86,p=0.064,两者表现相当。

临床应用与阅片要点

  • AI平台可作为主动脉扩张和CAC检出的辅助工具,但主动脉扩张特异度低于报告。
  • 临床报告对肺部病变和VCF的识别仍优于AI,AI对VCF特异度仅63.7%。
  • 肺气肿的AI与报告诊断表现无显著差异,AI敏感度80.6%、特异度66.7%。
  • AI处理失败情况:主动脉分割2例失败,钙化定量3例失败。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Research on implementation of artificial intelligence (AI) in radiology workflows and its impact on reports remains scarce. In this study, we aim to assess if an AI platform would perform better than clinical radiology reports in evaluating noncontrast chest computed tomography (CT) scans.

MATERIALS AND METHODS: Consecutive patients who had undergone noncontrast chest CT were retrospectively identified. The radiology reports were reviewed in a binary fashion for reporting of pulmonary lesions, pulmonary emphysema, aortic dilatation, coronary artery calcifications (CAC), and vertebral compression fractures (VCF). CT scans were then processed using an AI platform. The reports' findings and the AI results were subsequently compared to a consensus read by two board-certificated radiologists as reference.

RESULTS: A total of 100 patients (mean age: 64.2 ± 14.8 years; 57% males) were included in this study. Aortic segmentation and calcium quantification failed to be processed by AI in 2 and 3 cases, respectively. AI showed superior diagnostic performance in identifying aortic dilatation (AI: sensitivity: 96.3%, specificity: 81.4%, AUC: 0.89) vs (Reports: sensitivity: 25.9%, specificity: 100%, AUC: 0.63), p <0.001; and CAC (AI: sensitivity: 89.8%, specificity: 100, AUC: 0.95) vs (Reports: sensitivity: 75.4%, specificity: 94.9%, AUC: 0.85), p = 0.005. Reports had better performance than AI in identifying pulmonary lesions (Reports: sensitivity: 97.6%, specificity: 100%, AUC: 0.99) vs (AI: sensitivity: 92.8%, specificity: 82.4%, AUC: 0.88), p = 0.024; and VCF (Reports: sensitivity:100%, specificity: 100%, AUC: 1.0) vs (AI: sensitivity: 100%, specificity: 63.7%, AUC: 0.82), p <0.001. A comparable diagnostic performance was noted in identifying pulmonary emphysema on AI (sensitivity: 80.6%, specificity: 66.7%. AUC: 0.74) and reports (sensitivity: 74.2%, specificity: 97.1%, AUC: 0.86), p = 0.064.

CONCLUSION: Our results demonstrate that incorporating AI support platforms into radiology workflows can provide significant added value to clinical radiology reporting.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Yacoub B, Kabakus IM, Schoepf UJ, et al. Performance of an Artificial Intelligence-Based Platform Against Clinical Radiology Reports for the Evaluation of Noncontrast Chest CT. Acad Radiol. 2021. PMID: 33714665. doi:10.1016/j.acra.2021.02.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。