文献速递胸部CTMR

肺癌脏层胸膜表面侵犯的影像评估:CT与增强径向T1加权梯度回波3T MRI的比较

Imaging Assessment of Visceral Pleural Surface Invasion by Lung Cancer: Comparison of CT and Contrast-Enhanced Radial T1-Weighted Gradient Echo 3-Tesla MRI.
PubMed 文献 · Korean J Radiol · 2021-02-24

MRI肿瘤-胸膜界面边缘评估诊断VPSI的准确度91%、敏感度83%、特异度95%;CT与MRI在接触长度、肿块边缘角度、弓距与最大径比值预测VPSI方面无显著差异。MRI的优势在于清晰显示肿瘤-胸膜界面边缘。

要点

  • MRI肿瘤-胸膜界面不规则边缘诊断VPSI的敏感度83%、特异度95%、准确度91%。
  • CT与MRI在接触长度、肿块边缘角度、弓距/最大径比值预测VPSI上无显著差异。
  • 肿瘤-胸膜界面平滑与不规则的评估仅MRI可完成,CT无法辨别。

核心结论

  • 增强径向T1加权梯度回波3T MRI与CT在接触长度、肿块边缘角度、弓距与最大肿瘤直径比值预测VPSI方面诊断性能相等。
  • MRI的优势在于清晰描绘肿瘤-胸膜界面边缘,有助于VPSI检出。

研究设计与样本

  • 对比多排CT与自由呼吸径向三维脂肪抑制VIBE脉冲序列增强3T MRI。
  • VPSI分为PL1(无VPSI,侵犯脏层胸膜弹性层但未达表面)和PL2(有VPSI,完全侵犯脏层胸膜)。

关键影像表现/征象

  • MRI示无VPSI者21例中20例肿瘤-胸膜界面边缘平滑,有VPSI者12例中10例边缘不规则。
  • 肿瘤-胸膜界面平滑与不规则的区别仅MRI可评估,CT无法辨别。

诊断标准与关键数值

  • MRI肿瘤-胸膜界面边缘评估诊断VPSI的准确度91%、敏感度83%、特异度95%、阳性预测值91%、阴性预测值91%、F-score 87%。
  • CT与MRI在接触长度、肿块边缘角度、弓距与最大肿瘤直径比值预测VPSI方面,McNemar检验和ROC曲线分析显示无显著差异。

临床应用与阅片要点

  • 阅片时可利用增强3T径向VIBE MRI评估肿瘤-胸膜界面边缘平滑或规则,辅助判断VPSI。
  • CT与MRI在接触长度、肿块边缘角度、弓距/最大径比值方面诊断价值相当,可依据可用性选择。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3-tesla (3T) magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of visceral pleural surface invasion (VPSI). Visceral pleural invasion by non-small-cell lung cancer (NSCLC) can be classified into two types: PL1 (without VPSI), invasion of the elastic layer of the visceral pleura without reaching the visceral pleural surface, and PL2 (with VPSI), full invasion of the visceral pleura.

MATERIALS AND METHODS: Thirty-three patients with pathologically confirmed VPSI by NSCLC were retrospectively reviewed. Multidetector CT and contrast-enhanced 3T MRI with a free-breathing radial three-dimensional fat-suppressed volumetric interpolated breath-hold examination (VIBE) pulse sequence were compared in terms of the length of contact, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. Supplemental evaluation of the tumor-pleura interface (smooth versus irregular) could only be performed with MRI (not discernible on CT).

RESULTS: At the tumor-pleura interface, radial VIBE MRI revealed a smooth margin in 20 of 21 patients without VPSI and an irregular margin in 10 of 12 patients with VPSI, yielding an accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and F-score for VPSI detection of 91%, 83%, 95%, 91%, 91%, and 87%, respectively. The McNemar test and receiver operating characteristics curve analysis revealed no significant differences between the diagnostic accuracies of CT and MRI for evaluating the contact length, angle of mass margin, or arch distance-to-maximum tumor diameter ratio as predictors of VPSI.

CONCLUSION: The diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3T MRI and CT were equal in terms of the contact length, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. The advantage of MRI is its clear depiction of the tumor-pleura interface margin, facilitating VPSI detection.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang Y, Kwon W, Lee HY, et al. Imaging Assessment of Visceral Pleural Surface Invasion by Lung Cancer: Comparison of CT and Contrast-Enhanced Radial T1-Weighted Gradient Echo 3-Tesla MRI. Korean J Radiol. 2021. PMID: 33686817. doi:10.3348/kjr.2020.0955

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。