文献速递胸部技术与安全USCT

COVID-19患者肺部超声与胸部CT表现的相关性及肺负荷评估

Correlation between lung ultrasound and chest CT patterns with estimation of pulmonary burden in COVID-19 patients.
PubMed 文献 · Eur J Radiol · 2021-03-11

回顾性分析219例PCR确诊COVID-19且胸部CT异常的患者,比较肺部超声与CT对病灶模式的分辨能力及疾病负荷量化。超声正确识别217例(99%)阳性患者,但分区分析敏感度75%、特异度66%;超声阳性而CT阴性121例中,复查CT发现42例(38%)有COVID兼容病灶。结论认为超声有助病例识别,但与CT在病灶模式和严重度量化上仅中度相关。

要点

  • LUS对COVID-19病例识别价值高(99%患者被正确判为阳性),但分区敏感度75%、特异度66%。
  • LUS阳性而CT阴性者中38%复查CT可见COVID兼容病灶,提示存在假阴性CT或LUS假阳性。
  • LUS阳性肺区数量与LUS严重度评分在识别%WALV≤70%时AUC无差异,单用阳性区数即可区分。

关键影像表现/征象

  • LUS正确识别217例(99%)胸部CT异常的患者为阳性。
  • 分区分析LUS敏感度75%、特异度66%。
  • 121例(55%)LUS阳性而CT阴性,复查CT后42例(38%)见COVID兼容病灶。
  • LUS与CT的病变阳性区数、严重度评分和%WALV之间呈中度相关。

诊断标准与关键数值

  • LUS严重度评分与LUS阳性区数检测%WALV≤70%的AUC无差异。

临床应用与阅片要点

  • LUS可用于COVID-19病例识别,但分区判读需注意其敏感度75%、特异度66%的限制。
  • LUS阳性而CT阴性时,复查CT可发现部分COVID兼容病灶(38%)。
  • 单用LUS阳性肺区数即可区分%WALV≤70%的相关疾病负荷。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The capability of lung ultrasound (LUS) to distinguish the different pulmonary patterns of COVID-19 and quantify the disease burden compared to chest CT is still unclear.

METHODS: PCR-confirmed COVID-19 patients who underwent both LUS and chest CT at the Emergency Department were retrospectively analysed. In both modalities, twelve peripheral lung zones were identified and given a Severity Score basing on main lesion pattern. On CT scans the well-aerated lung volume (%WALV) was visually estimated. Per-patient and per-zone assessments of LUS classification performance taking CT findings as reference were performed, further revisioning the images in case of discordant results. Correlations between number of disease-positive lung zones, Severity Score and %WALV on both LUS and CT were assessed. The area under receiver operating characteristic curve (AUC) was calculated to determine LUS performance in detecting %WALV ≤ 70 %.

RESULTS: The study included 219 COVID-19 patients with abnormal chest CT. LUS correctly identified as positive 217 (99 %) patients, but per-zone analysis showed sensitivity = 75 % and specificity = 66 %. The revision of the 121 (55 %) cases with positive LUS and negative CT revealed COVID-compatible lesions in 42 (38 %) CT scans. Number of disease-positive zones, Severity Score and %WALV between LUS and CT showed moderate correlations. The AUCs for LUS Severity Score and number of LUS-positive zones did not differ in detecting %WALV ≤ 70 %.

CONCLUSION: LUS in COVID-19 is valuable for case identification but shows only moderate correlation with CT findings as for lesion patterns and severity quantification. The number of disease-positive lung zones in LUS alone was sufficient to discriminate relevant disease burden.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Rizzetto F, Perillo N, Artioli D, et al. Correlation between lung ultrasound and chest CT patterns with estimation of pulmonary burden in COVID-19 patients. Eur J Radiol. 2021. PMID: 33743491. doi:10.1016/j.ejrad.2021.109650

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。