文献速递胸部CTDR

COVID-19胸部CT病变范围及对胸片判读的影响

Extension of Coronavirus Disease 2019 on Chest CT and Implications for Chest Radiographic Interpretation.
PubMed 文献 · Radiol Cardiothorac Imaging · 2020-03-30

该回顾性研究纳入17例COVID-19患者的20对同日CT与胸片及20例对照胸片,用定量CT测量肺内磨玻璃/实变影质量(QCTmass),并由8名胸部放射科医师判读胸片。结果显示胸片检出肺内病变的中位敏感度25%、特异度90%,QCTmass与病变总体积是胸片可见性的显著决定因素。

要点

  • 胸片检出COVID-19肺内病变敏感度低(中位25%),特异度高(中位90%)。
  • QCTmass与病变总体积越大,胸片上病变越可能被看到(P<.001)。
  • CT上病变占肺面积3.2%±5.8%,投影后占13.9%±18.0%,胸片仅可辨投影图中位55.8%的面积。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To study the extent of pulmonary involvement in coronavirus 19 (COVID-19) with quantitative CT and to assess the impact of disease burden on opacity visibility on chest radiographs.

MATERIALS AND METHODS: This retrospective study included 20 pairs of CT scans and same-day chest radiographs from 17 patients with COVID-19, along with 20 chest radiographs of controls. All pulmonary opacities were semiautomatically segmented on CT images, producing an anteroposterior projection image to match the corresponding frontal chest radiograph. The quantitative CT lung opacification mass (QCTmass) was defined as (opacity attenuation value + 1000 HU)/1000 × 1.065 (g/mL) × combined volume (cm3) of the individual opacities. Eight thoracic radiologists reviewed the 40 radiographs, and a receiver operating characteristic curve analysis was performed for the detection of lung opacities. Logistic regression analysis was performed to identify factors affecting opacity visibility on chest radiographs.

RESULTS: The mean QCTmass per patient was 72.4 g ± 120.8 (range, 0.7-420.7 g), and opacities occupied 3.2% ± 5.8 (range, 0.1%-19.8%) and 13.9% ± 18.0 (range, 0.5%-57.8%) of the lung area on the CT images and projected images, respectively. The radiographs had a median sensitivity of 25% and specificity of 90% among radiologists. Nineteen of 186 opacities were visible on chest radiographs, and a median area of 55.8% of the projected images was identifiable on radiographs. Logistic regression analysis showed that QCTmass (P < .001) and combined opacity volume (P < .001) significantly affected opacity visibility on radiographs.

CONCLUSION: QCTmass varied among patients with COVID-19. Chest radiographs had high specificity for detecting lung opacities in COVID-19 but a low sensitivity. QCTmass and combined opacity volume were significant determinants of opacity visibility on radiographs.Earlier incorrect version appeared online. This article was corrected on April 6, 2020 and December 14, 2020.Supplemental material is available for this article.© RSNA, 2020.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Choi H, Qi X, Yoon SH, et al. Extension of Coronavirus Disease 2019 on Chest CT and Implications for Chest Radiographic Interpretation. Radiol Cardiothorac Imaging. 2020. PMID: 33778565. doi:10.1148/ryct.2020200107

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。