CT引导下同时多发性肺结节微弹簧圈定位的可行性与安全性
回顾性队列研究纳入288例患者,比较同侧肺同时多个(36例79个结节)与单个(252例252个结节)微弹簧圈定位后行VATS。两组技术成功率分别为96.2%和98.0%(p=0.326),但多发定位组任何并发症(气胸或肺出血)发生率显著更高(55.6% vs 21.8%,p<0.001),气胸发生率亦显著更高,而肺出血发生率两组无显著差异(p=0.385)。结论认为尽管气胸发生率更高,同时多结节定位临床可行且安全。
要点
- 多发结节同时定位技术成功率96.2%(76/79),与单发定位98.0%(247/252)无显著差异(p=0.326)。
- 多发定位组任何并发症(气胸或肺出血)发生率55.6%,显著高于单发组的21.8%(p<0.001)。
- 多发定位组气胸发生率显著高于单发组(p<0.001),但两组肺出血发生率无显著差异(p=0.385)。
诊断标准与关键数值
- 多发定位组技术成功率96.2%(76/79),单发定位组98.0%(247/252),两组比较p=0.326。
- 多发定位组任何并发症(气胸或肺出血)发生率55.6%,单发定位组21.8%,p<0.001。
- 多发定位组气胸发生率显著高于单发定位组(p<0.001)。
- 两组肺出血发生率差异无统计学意义(p=0.385)。
临床应用与阅片要点
- 同时多发性肺结节微弹簧圈定位技术成功率高,可作为VATS术前定位的可行选择。
- 多发定位时气胸发生率明显增高,术后需关注气胸相关并发症。
- 肺出血发生率在多发与单发定位间无显著差异。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate retrospectively the feasibility and safety of simultaneous multiple microcoil localizations of multiple pulmonary nodules prior to video-assisted thoracoscopic surgery (VATS).
METHODS: This retrospective cohort study enrolled 288 consecutive patients, who underwent computed tomography (CT)-guided microcoil localization and subsequent VATS at our academic hospital between July 2017 and June 2018. Of these patients, 36 with 79 pulmonary nodules undergoing simultaneous multiple microcoil localizations in the ipsilateral lung were designated the multiple localization group; the remaining 252 with 252 pulmonary nodules undergoing single microcoil localization were designated the single localization group. The main outcomes were the technical success and complication rates of the localization procedures. The Student t test and Mann-Whitney U test were used for continuous variables. The chi-squared test and logistic regression analysis were used to assess dichotomous variables.
RESULTS: The localization technical success rates of the multiple and single localization groups were 96.2% (76/79) and 98.0% (247/252), respectively (p = 0.326). The rate of any complication (pneumothorax or pulmonary hemorrhage) was significantly higher in the multiple localization than in the single localization group (55.6% vs 21.8%, respectively; p < 0.001). The incidence of pneumothorax was significantly higher in the multiple localization than in the single localization group (p < 0.001). The difference between the incidence of pulmonary hemorrhage in the 2 groups was not significant (p = 0.385).
CONCLUSIONS: Although preoperative CT-guided simultaneous microcoil localizations of multiple pulmonary nodules produced a significantly higher incidence of pneumothorax, the localizations were clinically feasible and safe.
KEY POINTS: • Simultaneous preoperative CT-guided microcoil localizations of multiple pulmonary nodules are clinically feasible and safe. • Simultaneous microcoil localizations of multiple pulmonary nodules produced a significantly higher incidence of pneumothorax.
引用
- Hu L, Gao J, Hong N, et al. Simultaneous preoperative computed tomography-guided microcoil localizations of multiple pulmonary nodules. Eur Radiol. 2021. PMID: 33666697. doi:10.1007/s00330-021-07772-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。