基于平扫CT的影像组学特征用于筛查胸主动脉夹层:一项多中心研究
本研究回顾性纳入4个医学中心共378例接受平扫胸部CT及CTA或MRI检查的患者,基于平扫CT提取影像组学特征构建逻辑回归模型筛查胸主动脉夹层。影像组学特征在训练集、验证集和外部测试集的AUC分别为0.91、0.92和0.90,外部测试集准确度90.5%、敏感度85.7%、特异度91.7%。该方法可能作为胸主动脉夹层的潜在筛查工具。
要点
- 平扫CT影像组学特征对胸主动脉夹层有较好判别能力,外部测试集AUC为0.90。
- 外部测试集敏感度85.7%、特异度91.7%,阴性预测值96.5%。
- 原文指出该影像组学特征预测性能优于当前临床模型。
诊断标准与关键数值
- 影像组学特征诊断胸主动脉夹层的AUC在训练集为0.91(95%CI 0.86-0.95),验证集为0.92(95%CI 0.86-0.98),外部测试集为0.90(95%CI 0.82-0.98)。
- 外部测试集诊断准确度90.5%、敏感度85.7%、特异度91.7%、阳性预测值70.6%、阴性预测值96.5%。
- 预测诊断与胸主动脉夹层概率高度一致。
临床应用与阅片要点
- 平扫CT影像组学特征可用于胸主动脉夹层的筛查评估,外部测试集显示较高阴性预测值(96.5%)。
- 原文指出该影像组学特征预测性能优于当前临床模型。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To develop a non-contrast CT-based radiomic signature to effectively screen for thoracic aortic dissections (ADs).
METHODS: We retrospectively enrolled 378 patients who underwent non-contrast chest CT scans along with CT angiography or MRI from 4 medical centers. The training and validation sets were from 3 centers, while the external test set was from a 4th center. Radiomic features were extracted from non-contrast CT images. The radiomic signature was created on the basis of selected features by a logistic regression algorithm. The area under the curve (AUC) of the receiver operating characteristic (ROC) curve, accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were conducted to assess the predictive ability of radiomic signature.
RESULTS: The radiomic signature demonstrated AUCs of 0.91 (95% confidence interval [CI], 0.86-0.95) in the training set, 0.92 (95% CI, 0.86-0.98) in the validation set, and 0.90 (95% CI, 0.82-0.98) in the external test set. The predicted diagnosis was in good agreement with the probability of thoracic AD. In the external test group, the diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 90.5%, 85.7%, 91.7%, 70.6%, and 96.5%, respectively.
CONCLUSIONS: A radiomic signature based on non-contrast CT images can effectively predict thoracic ADs. This method may serve as a potential screening tool for thoracic ADs.
KEY POINTS: • The non-contrast CT-based radiomic signature can effectively predict the thoracic aortic dissections. • This radiomic signature shows better predictive performance compared to the current clinical model. • This prediction method may be a potential tool for screening thoracic aortic dissections.
引用
- Guo Y, Chen X, Lin X, et al. Non-contrast CT-based radiomic signature for screening thoracic aortic dissections: a multicenter study. Eur Radiol. 2021. PMID: 33755755. doi:10.1007/s00330-021-07768-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。