COVID-19肺炎胸部CT分级系统的比较
本研究为病例对照研究,纳入100例疑似COVID-19患者(50例确诊,50例无COVID-19),8名放射科医生独立使用CO-RADS、COVID-RADS、RSNA专家共识和BSTI指南对胸部CT进行评分。结果显示CO-RADS和BSTI的诊断性能优于COVID-RADS和RSNA,所有系统均具有合理的观察者间一致性。
要点
- CO-RADS和BSTI的AUC均为0.84,高于COVID-RADS(0.80)和RSNA(0.81)。
- 各系统观察者间一致性中等(Cohen's kappa 0.61-0.63)。
- 除「无肺炎」分类外,COVID-19怀疑程度与RT-PCR阳性率相关(ρ=1.0)。
诊断标准与关键数值
- 平均AUC:CO-RADS 0.84(95%CI 0.83-0.85),COVID-RADS 0.80(0.78-0.81),RSNA声明 0.81(0.79-0.82),BSTI声明 0.84(0.812-0.86)。
- 观察者间平均Cohen's kappa:CO-RADS 0.62(95%CI 0.58-0.66),COVID-RADS 0.63(0.58-0.68),RSNA声明 0.63(0.57-0.69),BSTI声明 0.61(0.58-0.64)。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the performance and interobserver agreement of the COVID-19 Reporting and Data System (CO-RADS), the COVID-19 imaging reporting and data system (COVID-RADS), the RSNA expert consensus statement, and the British Society of Thoracic Imaging (BSTI) guidance statement.
MATERIALS AND METHODS: In this case-control study, total of 100 symptomatic patients suspected of having COVID-19 were included: 50 patients with COVID-19 (59±17 years, 38 men) and 50 patients without COVID-19 (65±24 years, 30 men). Eight radiologists independently scored chest CT images of the cohort according to each reporting system. The area under the receiver operating characteristic curves (AUC) and interobserver agreements were calculated and statistically compared across the systems.
RESULTS: A total of 800 observations were made for each system. The level of suspicion of COVID-19 correlated with the RT-PCR positive rate except for the "negative for pneumonia" classifications in all the systems (Spearman's coefficient: ρ=1.0, P=<.001 for all the systems). Average AUCs were as follows: CO-RADS, 0.84 (95% confidence interval, 0.83-0.85): COVID-RADS, 0.80 (0.78-0.81): the RSNA statement, 0.81 (0.79-0.82): and the BSTI statement, 0.84 (0.812-0.86). Average Cohen's kappa across observers was 0.62 (95% confidence interval, 0.58-0.66), 0.63 (0.58-0.68), 0.63 (0.57-0.69), and 0.61 (0.58-0.64) for CO-RADS, COVID-RADS, the RSNA statement and the BSTI statement, respectively. CO-RADS and the BSTI statement outperformed COVID-RADS and the RSNA statement in diagnostic performance (P=.<.05 for all the comparison).
CONCLUSIONS: CO-RADS, COVID-RADS, the RSNA statement and the BSTI statement provided reasonable performances and interobserver agreements in reporting CT findings of COVID-19.
引用
- Inui S, Kurokawa R, Nakai Y, et al. Comparison of Chest CT Grading Systems in Coronavirus Disease 2019 (COVID-19) Pneumonia. Radiol Cardiothorac Imaging. 2020. PMID: 33778648. doi:10.1148/ryct.2020200492
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。