COVID-19肺炎与肺栓塞的双能CT肺动脉造影定性与定量评估
回顾性纳入74例COVID-19肺炎患者行双能CT肺动脉造影,评估定性与定量肺灌注参数。约20.2%(15/74)存在肺动脉充盈缺损,多为闭塞性(28/44)且位于段及亚段动脉。有充盈缺损者肺部阴影更广泛密集(CT严重度评分24±4 vs 20±8,p=0.028);定量灌注统计在低SpO2(p=0.003)、插管(p=0.006)及肺动脉充盈缺损(p=0.007)患者中显著降低。
要点
- 约20.2%(15/74)COVID-19肺炎患者DECT-PA检出肺动脉充盈缺损,多为闭塞性且位于段/亚段动脉。
- 有充盈缺损者CT严重度评分更高(24±4 vs 20±8,p=0.028),提示肺部病变更重。
- 定量灌注统计在低SpO2、插管及肺动脉充盈缺损患者中显著降低。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To assess differences in qualitative and quantitative parameters of pulmonary perfusion from dual-energy computed tomography (CT) pulmonary angiography (DECT-PA) in patients with COVID-19 pneumonia with and without pulmonary embolism (PE).
MATERIALS AND METHODS: This retrospective institutional review board-approved study included 74 patients (mean age 61±18 years, male:female 34:40) with COVID-19 pneumonia in two countries (one with 68 patients, and the other with six patients) who underwent DECT-PA on either dual-source (DS) or single-source (SS) multidetector CT machines. Images from DS-DECT-PA were processed to obtain virtual mono-energetic 40 keV (Mono40), material decomposition iodine (MDI) images and quantitative perfusion statistics (QPS). Two thoracic radiologists determined CT severity scores based on type and extent of pulmonary opacities, assessed presence of PE, and pulmonary parenchymal perfusion on MDI images. The QPS were calculated from the CT Lung Isolation prototype (Siemens). The correlated clinical outcomes included duration of hospital stay, intubation, SpO2 and death. The significance of association was determined by receiver operating characteristics and analysis of variance.
RESULTS: One-fifth (20.2%, 15/74 patients) had pulmonary arterial filling defects; most filling defects were occlusive (28/44) located in the segmental and sub-segmental arteries. The parenchymal opacities were more extensive and denser (CT severity score 24±4) in patients with arterial filling defects than without filling defects (20±8; p=0.028). Ground-glass opacities demonstrated increased iodine distribution; mixed and consolidative opacities had reduced iodine on DS-DECT-PA but increased or heterogeneous iodine content on SS-DECT-PA. QPS were significantly lower in patients with low SpO2 (p=0.003), intubation (p=0.006), and pulmonary arterial filling defects (p=0.007).
CONCLUSION: DECT-PA QPS correlated with clinical outcomes in COVID-19 patients.
引用
- Arru CD, Digumarthy SR, Hansen JV, et al. Qualitative and quantitative DECT pulmonary angiography in COVID-19 pneumonia and pulmonary embolism. Clin Radiol. 2021. PMID: 33714541. doi:10.1016/j.crad.2021.02.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。