T1加权MRI最大信号强度对腮腺肿瘤的鉴别诊断价值及病理对照
结果显示Warthin瘤T1-max-SIR高于多形性腺瘤(p<0.001)和恶性肿瘤(p<0.001),多形性腺瘤与恶性肿瘤间无显著差异(p=0.151)。T1-max-SIR鉴别Warthin瘤与多形性腺瘤的AUC为0.901(敏感度91.1%、特异度82.9%),鉴别Warthin瘤与恶性肿瘤的AUC为0.851(敏感度88.9%、特异度78.8%)。
要点
- T1-max-SIR在Warthin瘤中高于多形性腺瘤和恶性肿瘤,多形性腺瘤与恶性肿瘤间无显著差异。
- T1-max-SIR鉴别Warthin瘤与多形性腺瘤AUC 0.901,敏感度91.1%、特异度82.9%。
- T1-max-SIR鉴别Warthin瘤与恶性肿瘤AUC 0.851,敏感度88.9%、特异度78.8%。
关键影像表现/征象
- Warthin瘤的T1-max-SIR高于多形性腺瘤(p<0.001)和恶性肿瘤(p<0.001)。
- 多形性腺瘤与恶性肿瘤之间的T1-max-SIR无显著差异(p=0.151)。
诊断标准与关键数值
- T1-max-SIR鉴别Warthin瘤与多形性腺瘤的AUC为0.901,敏感度91.1%、特异度82.9%。
- T1-max-SIR鉴别Warthin瘤与恶性肿瘤的AUC为0.851,敏感度88.9%、特异度78.8%。
- 观察者间一致性ICC=0.989(95%CI 0.985-0.992)。
临床应用与阅片要点
- 在T1加权MRI上测量肿瘤最大信号强度并以脊髓平均信号强度标准化,计算T1-max-SIR,有助于鉴别Warthin瘤与多形性腺瘤及恶性肿瘤。
- 多形性腺瘤与恶性肿瘤的T1-max-SIR无显著差异,鉴别两者时需结合其他影像征象。
- T1-max-SIR测量具有极好的观察者间一致性(ICC=0.989),可作为可重复的定量指标。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate the efficacy of the maximum signal intensity of tumour on T1-weighted magnetic resonance imaging (MRI) images for differentiating Warthin's tumours (WTs) from pleomorphic adenomas (PAs) and malignant tumours (MTs).
MATERIALS AND METHODS: One hundred and fifty-four histopathologically confirmed parotid tumours, including 76 PAs, 45 WTs, and 33 MTs, were analysed. MRI results were compared with pathological findings. The maximum signal intensity of tumour and the average signal intensity of spinal cord were measured on T1-weighted images, then the tumour-to-spinal cord signal intensity ratio (T1-max-SIR) was calculated. The distribution of T1-max-SIRs among the three groups of tumours was analysed using the Mann-Whitney U-test. Receiver operating characteristic curves were generated to assess the ability of T1-max-SIRs to differentiate parotid tumours. In addition, the interobserver agreement between readers was assessed using interclass correlation coefficient (ICC).
RESULTS: T1-max-SIRs were higher in WTs than in PAs (p<0.001) and MTs (p<0.001), and no significant difference was found between PAs and MTs (p=0.151). The area under the curve (AUC) of T1-max-SIRs for differentiating WTs from PAs was 0.901, with a sensitivity of 91.1% and a specificity of 82.9%. The AUC of T1-max-SIRs for differentiating WTs from MTs was 0.851, with a sensitivity of 88.9% and a specificity of 78.8%. Readers had excellent interobserver agreement on T1-max-SIRs (ICC = 0.989; 95% confidence interval, 0.985-0.992).
CONCLUSIONS: T1-max-SIRs can be useful for differentiating WTs from PAs and MTs with high diagnostic efficiency.
引用
- Wei PY, Shao C, Huan T, et al. Diagnostic value of maximum signal intensity on T1-weighted MRI images for differentiating parotid gland tumours along with pathological correlation. Clin Radiol. 2021. PMID: 33731262. doi:10.1016/j.crad.2021.02.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。