延迟增强MRA评估急性缺血性卒中颈动脉球通畅性:准确性及阅片者间/内一致性研究
本研究回顾性分析单中心32例ICA闭塞并行血栓切除术患者,比较早期与延迟增强MRA评估颈动脉球通畅性的准确性及一致性,以DSA为参考标准。早期增强MRA准确性有限(69%),附加延迟序列后准确性提高至82%(P<.001),阅片者间一致性从κ=0.42升至κ=0.56(P=.07)。
要点
- 早期增强MRA评估颈动脉球通畅性准确性有限(69%),附加延迟序列后提高至82%。
- 延迟增强MRA序列使阅片者间一致性从κ=0.42升至κ=0.56(P=.07)。
- 阅片者通过延迟序列纠正了43%-77%(平均59%)的早期增强MRA错误诊断。
诊断标准与关键数值
- 早期增强MRA评估颈动脉球通畅性准确性69%(95%CI 59%-79%),阅片者间一致性κ=0.42(95%CI 0.27-0.55)。
- 附加延迟增强MRA序列后准确性82%(95%CI 73%-91%;P<.001),阅片者间一致性κ=0.56(95%CI 0.41-0.73;P=.07)。
- 阅片者通过延迟序列纠正了43%-77%(平均59%)的早期增强MRA错误诊断。
- 5名阅片者中,3名阅片者内一致性几乎完美,1名显著,1名中等。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: CTA has shown limited accuracy and reliability in distinguishing tandem occlusions and pseudo-occlusions on initial acute stroke imaging. The utility of early and delayed contrast-enhanced MRA in this setting is unknown. We aimed to assess the accuracy and reliability of early and delayed contrast-enhanced MRA for carotid bulb patency in patients with acute ischemic stroke.
MATERIALS AND METHODS: We retrospectively reviewed patients who had ICA occlusion and underwent thrombectomy with preprocedural early and delayed contrast-enhanced MRA in a single comprehensive stroke center. During 2 sessions, 10 raters independently assessed 32 cases with early contrast-enhanced MRA (with an additional delayed contrast-enhanced MRA sequence during the second reading session). Their judgments were compared with DSA as a reference standard. Accuracy and interrater agreement were measured. Five raters undertook a third reading session to assess intrarater agreement.
RESULTS: Accuracy for the assessment of carotid bulb patency with early contrast-enhanced MRA was limited (69%; 95% CI, 59%-79%), with moderate interrater agreement (κ = 0.42; 95% CI, 0.27-0.55). The second reading with an additional delayed contrast-enhanced MRA sequence improved both accuracy (82%; 95% CI, 73%-91%; P < .001) (raters corrected 43%-77% of incorrect diagnoses with early contrast-enhanced MRA alone; mean = 59%) and interrater agreement (κ = 0.56; 95% CI, 0.41-0.73; P = .07). Intrarater agreement was almost perfect, substantial, and moderate for 3, 1, and 1 raters.
CONCLUSIONS: Early contrast-enhanced MRA has limited accuracy and repeatability for the evaluation of carotid bulb patency in acute ischemic stroke. The additional delayed contrast-enhanced MRA sequence may improve accuracy and reliability.
引用
- Boisseau W, Benaissa A, Fahed R, et al. Delayed Contrast-Enhanced MR Angiography for the Assessment of Internal Carotid Bulb Patency in the Context of Acute Ischemic Stroke: An Accuracy, Interrater, and Intrarater Agreement Study. AJNR Am J Neuroradiol. 2021. PMID: 33707285. doi:10.3174/ajnr.A7054
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。