动脉自旋标记MR成像检测致痫区的诊断准确性:系统综述与荟萃分析
该系统综述与荟萃分析纳入6项研究共174例患者,评估动脉自旋标记(ASL)定位致痫区的诊断准确性,以发作症状灶为参考标准。ASL汇总敏感度为0.74(95%CI 0.65-0.82),汇总特异度为0.35(95%CI 0.03-0.90),SROC曲线下面积为0.73(95%CI 0.69-0.76)。ASL结果阳性时定位致痫区的准确性为0.88,致痫区可表现为高灌注或低灌注。
要点
- ASL定位致痫区汇总敏感度0.74、特异度0.35,敏感度中等而特异度很低。
- ASL阳性时定位准确性为0.88,提示阳性结果对致痫区定位有较高价值。
- 致痫区在ASL上可表现为高灌注或低灌注,阅片时需双向寻找灌注异常。
局限性
- 由于纳入标准严格,纳入的研究数量较少。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: A noninvasive, safe, and economic imaging technique is required to identify epileptogenic lesions in the brain.
PURPOSE: Our aim was to perform a meta-analysis evaluating the accuracy of arterial spin-labeling in localizing the epileptic focus in the brain and the changes in the blood perfusion in these regions.
DATA SOURCES: Our sources were the PubMed and EMBASE data bases.
STUDY SELECTION: English language studies that assessed the diagnostic accuracy of arterial spin-labeling for detecting the epileptogenic zone up to July 2019 were included.
DATA ANALYSIS: The symptomatogenic foci of seizures in the brain were determined and used as the references. The relevant studies were evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. The outcomes were evaluated using the pooled sensitivity, pooled specificity, pooled accuracy, diagnostic odds ratio, area under the summary receiver operating characteristic curve, and likelihood ratio.
DATA SYNTHESIS: Six studies that included 174 patients qualified for this meta-analysis. The pooled sensitivity, pooled specificity, and area under the summary receiver operating characteristic curve were 0.74 (95% CI, 0.65-0.82), 0.35 (95% CI, 0.03-0.90), and 0.73 (95% CI, 0.69-0.76), respectively. The accuracy of arterial spin-labeling for localizing the epileptic focus was 0.88 (accuracy in arterial spin-labeling/all perfusion changes in arterial spin-labeling) in cases of a positive arterial spin-labeling result. The epileptogenic zone exhibited hyperperfusion or hypoperfusion.
LIMITATIONS: Only a few studies were enrolled due to the strict inclusion criteria.
CONCLUSIONS: Arterial spin-labeling can be used for assessing, monitoring, and reviewing, postoperatively, patients with epilepsy. Blood perfusion changes in the brain may be closely related to the seizure time and pattern.