文献速递神经MR

生成对抗网络合成缺失T1与FLAIR序列用于多序列脑肿瘤分割模型

Generative Adversarial Networks to Synthesize Missing T1 and FLAIR MRI Sequences for Use in a Multisequence Brain Tumor Segmentation Model.
PubMed 文献 · Radiology · 2021-03-09

该回顾性研究训练两个生成对抗网络,分别由增强T1生成T1、由T2生成FLAIR,并在BRATS 2017的210例胶质母细胞瘤及本机构46例胶质母细胞瘤和21例中枢神经系统淋巴瘤上验证。合成图像的结构相似指数中位数0.76–0.92,替换缺失序列后分割DSC中位数为0.71–0.97,提示合成图像可作为深度学习模型输入用于序列缺失时。

要点

  • 仅替换T1时分割DSC最高(全病灶0.97、FLAIR高信号0.95、强化区0.92)。
  • 同时替换T1和FLAIR时分割DSC最低(全病灶0.82、FLAIR高信号0.71、强化区0.92)。
  • 合成图像质量用MSE和SSI评估,T1的SSI中位数0.82–0.92,FLAIR为0.76–0.92。

关键影像表现/征象

  • 生成的T1加权图像中位MSE为0.005–0.013,中位SSI为0.82–0.92。
  • 生成的FLAIR图像中位MSE为0.004–0.103,中位SSI为0.76–0.92。

诊断标准与关键数值

  • 同时替换T1和FLAIR时,全病灶、FLAIR高信号、强化区分割中位DSC分别为0.82、0.71、0.92。
  • 仅替换FLAIR时,全病灶、FLAIR高信号、强化区分割中位DSC分别为0.84、0.74、0.97。
  • 仅替换T1时,全病灶、FLAIR高信号、强化区分割中位DSC分别为0.97、0.95、0.92。

临床应用与阅片要点

  • 序列缺失时可考虑用GAN合成图像替代输入多序列分割模型,但需注意同时替换T1和FLAIR时FLAIR高信号分割DSC降至0.71。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Missing MRI sequences represent an obstacle in the development and use of deep learning (DL) models that require multiple inputs. Purpose To determine if synthesizing brain MRI scans using generative adversarial networks (GANs) allows for the use of a DL model for brain lesion segmentation that requires T1-weighted images, postcontrast T1-weighted images, fluid-attenuated inversion recovery (FLAIR) images, and T2-weighted images. Materials and Methods In this retrospective study, brain MRI scans obtained between 2011 and 2019 were collected, and scenarios were simulated in which the T1-weighted images and FLAIR images were missing. Two GANs were trained, validated, and tested using 210 glioblastomas (GBMs) (Multimodal Brain Tumor Image Segmentation Benchmark [BRATS] 2017) to generate T1-weighted images from postcontrast T1-weighted images and FLAIR images from T2-weighted images. The quality of the generated images was evaluated with mean squared error (MSE) and the structural similarity index (SSI). The segmentations obtained with the generated scans were compared with those obtained with the original MRI scans using the dice similarity coefficient (DSC). The GANs were validated on sets of GBMs and central nervous system lymphomas from the authors' institution to assess their generalizability. Statistical analysis was performed using the Mann-Whitney, Friedman, and Dunn tests. Results Two hundred ten GBMs from the BRATS data set and 46 GBMs (mean patient age, 58 years ± 11 [standard deviation]; 27 men [59%] and 19 women [41%]) and 21 central nervous system lymphomas (mean patient age, 67 years ± 13; 12 men [57%] and nine women [43%]) from the authors' institution were evaluated. The median MSE for the generated T1-weighted images ranged from 0.005 to 0.013, and the median MSE for the generated FLAIR images ranged from 0.004 to 0.103. The median SSI ranged from 0.82 to 0.92 for the generated T1-weighted images and from 0.76 to 0.92 for the generated FLAIR images. The median DSCs for the segmentation of the whole lesion, the FLAIR hyperintensities, and the contrast-enhanced areas using the generated scans were 0.82, 0.71, and 0.92, respectively, when replacing both T1-weighted and FLAIR images; 0.84, 0.74, and 0.97 when replacing only the FLAIR images; and 0.97, 0.95, and 0.92 when replacing only the T1-weighted images. Conclusion Brain MRI scans generated using generative adversarial networks can be used as deep learning model inputs in case MRI sequences are missing. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Zhong in this issue. An earlier incorrect version of this article appeared online. This article was corrected on April 12, 2021.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Conte GM, Weston AD, Vogelsang DC, et al. Generative Adversarial Networks to Synthesize Missing T1 and FLAIR MRI Sequences for Use in a Multisequence Brain Tumor Segmentation Model. Radiology. 2021. PMID: 33687284. doi:10.1148/radiol.2021203786

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。