MAP-MRI扩散模型在弥漫性胶质瘤分级中的初步应用
结果显示,II级胶质瘤的NG、NGAx、NGRad值低于III级(AUC分别为0.823、0.835、0.838,P<0.05);与IV级相比,II级的NG、NGAx、NGRad、RTAP、RTOP值更低而QIV更高(AUC分别为0.923、0.929、0.923、0.793、0.822、0.769,P<0.05)。结论认为定量MAP-MRI参数可在术前区分II级与III级、II级与IV级胶质瘤,但不能区分III级与IV级。
要点
- MAP-MRI参数NG、NGAx、NGRad在区分II级与III级胶质瘤时AUC均>0.8
- II级与IV级胶质瘤的NG、NGAx、NGRad、RTAP、RTOP、QIV均有显著差异,AUC最高达0.929
- MAP-MRI参数不能区分III级与IV级胶质瘤
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic -->performance of mean apparent propagator-magnetic resonance imaging (MAP-MRI) in distinguishing the grades of diffuse gliomas.
METHOD: Thirty-six patients with pathologically confirmed diffuse gliomas were enrolled in this study. MAP-MRI parameters were measured in the parenchymal area of the tumour: non-Gaussianity (NG), non-Gaussianity axial (NGAx), non-Gaussianity vertical (NGRad), Q-space inverse variance (QIV), return to the origin probability (RTOP), return to the axis probability (RTAP), return to the plane probability (RTPP), and mean square displacement (MSD). Differences in the parameters between any two grades were compared, the characteristics of the parameters for different diffuse glioma grades were analysed, and receiver operating characteristic (ROC) curves were plotted to analyse the diagnostic value of each parameter.
RESULTS: Compared with grade III gliomas, grade II gliomas had lower NG, NGAx and NGRad values. NG, NGAx and NGRad had great area under the ROC curve (AUC) values (0.823, 0.835, and 0.838, P < 0.05). Compared with those of grade IV glioma, the NG, NGAx, NGRad, RTAP and RTOP values for grade II glioma were lower, the QIV values were higher (all P < 0.05). NG, NGAx, NGRad, RTAP, RTOP and QIV had great area under the ROC curve (AUC) values (0.923, 0.929, 0.923,0.793,0.822, and 0.769, P < 0.05).
CONCLUSIONS: Quantitative MAP-MRI parameters can distinguish grade II and III and grade II and IV gliomas before surgery but not grade III and IV gliomas. Thus, these parameters have clinical guiding value in the noninvasive preoperative evaluation of tumour pathological grading.
引用
- Wang P, Weng L, Xie S, et al. Primary application of mean apparent propagator-MRI diffusion model in the grading of diffuse glioma. Eur J Radiol. 2021. PMID: 33721768. doi:10.1016/j.ejrad.2021.109622
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。