文献速递神经CT

双层探测器光谱CT作为胶质瘤术前评估的补充方法

Dual-layer detector spectral CT-a new supplementary method for preoperative evaluation of glioma.
PubMed 文献 · Eur J Radiol · 2021-03-11

前瞻性纳入99例胶质瘤患者,比较双层探测器光谱CT测量的碘浓度与CT强化程度在评估肿瘤分级及分子标志物中的价值。结果显示,高级别胶质瘤的碘浓度和强化程度均显著高于低级别胶质瘤(p<0.001),碘浓度诊断高级别胶质瘤的AUC为0.931,诊断III级胶质瘤的AUC为0.865,且碘浓度与Ki-67增殖指数呈显著正相关(r=0.679)。结论认为该技术可作为胶质瘤术前分级和预后评估的补充方法。

要点

  • 碘浓度诊断高级别胶质瘤的AUC为0.931(95%CI 0.882-0.979),诊断III级胶质瘤的AUC为0.865(95%CI 0.779-0.952)。
  • 高级别胶质瘤的碘浓度和CT强化程度均显著高于低级别胶质瘤(p<0.001)。
  • 碘浓度与Ki-67标记指数呈显著正相关(r=0.679,p<0.001)。

关键影像表现/征象

  • 高级别胶质瘤的碘浓度和CT强化程度均显著高于低级别胶质瘤(p<0.001)。
  • III级胶质瘤的碘浓度显著高于II级胶质瘤(p<0.001)。

诊断标准与关键数值

  • 碘浓度诊断高级别胶质瘤的AUC为0.931(95%CI 0.882-0.979,p<0.001)。
  • 碘浓度诊断III级胶质瘤的AUC为0.865(95%CI 0.779-0.952,p<0.001)。
  • 碘浓度与Ki-67标记指数呈显著正相关(r=0.679,p<0.001)。
  • 碘浓度与IDH突变、染色体1p/19q缺失状态的相关性被检验,但原文摘要未报告具体结果。

临床应用与阅片要点

  • 阅片时可关注双层探测器光谱CT测得的碘浓度,作为胶质瘤术前分级的补充信息。
  • 碘浓度与Ki-67增殖指数的正相关提示其可能反映肿瘤增殖活性。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the value of the iodine concentration (IC) measured by dual-layer detector spectral CT (DLDSCT) in evaluating the factors related to the treatment scheme and survival prognosis of patients with glioma.

METHODS: From 2018 to 2019, we prospectively collected the data of 99 patients with glioma. The degree of CT enhancement and the IC of low grade gliomas (LGGs, II), high grade gliomas (HGGs, III and IV), grade II and III gliomas, were compared. The predictive performance of the degree of CT enhancement and IC was examined via receiver operating characteristic (ROC) analysis. The correlations between IC and Ki-67 labeling index, isocitrate dehydrogenase (IDH) mutation, chromosome 1p/19q deletion status of the tumor were examined.

RESULTS: Both IC and the degree of CT enhancement of patients with HGG were significantly higher than those of patients with LGG (p < 0.001; χ2 =41.707, p < 0.001); IC had large area under the ROC curve for diagnostic HGG (0.931; 95 % CI: 0.882-0.979; p < 0.001). The IC in the grade III gliomas was significantly higher than that in grade II gliomas (p < 0.001); IC had a large area under the ROC curve for diagnostic grade III gliomas (0.865; 95 % CI: 0.779-0.952; p < 0.001). There was a significant positive correlation between IC and Ki-67 LI (r = 0.679; p < 0.001).

CONCLUSIONS: The DLDSCT technology can be used as a supplementary method to provide more information for preoperative grading of the gliomas and the prognosis assessment of the patients.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Yingying L, Zhe Z, Xiaochen W, et al. Dual-layer detector spectral CT-a new supplementary method for preoperative evaluation of glioma. Eur J Radiol. 2021. PMID: 33730659. doi:10.1016/j.ejrad.2021.109649

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。