文献速递神经骨肌MR

螺旋梯度回波序列用于脊柱增强抑脂T1WI的定性与定量分析

Qualitative and Quantitative Analysis of a Spiral Gradient Echo Sequence for Contrast-Enhanced Fat-Suppressed T1-Weighted Spine Magnetic Resonance Imaging.
PubMed 文献 · Invest Radiol · 2021-01-01

螺旋序列在整体图像质量、病灶显示及神经根可见性方面优于TSE,且扫描时间更短;与放射状序列相比病灶显示更优,但神经根可见性二者相当。

要点

  • 螺旋3D GRE序列扫描时间114.7±11秒,短于放射状3D GRE的216.7±2秒和TSE的266.7±82秒。
  • 螺旋序列整体图像质量中位评分5(4-5),优于TSE的3(3-4)和放射状序列的4(4-5)(均P<0.001)。
  • 螺旋序列病灶显示评分4(4-5),优于放射状序列4(3-5)(P=0.01)和TSE 4(3-4)(P=0.04)。

关键影像表现/征象

  • 螺旋序列整体图像质量中位评分5(4-5),TSE为3(3-4),放射状序列为4(4-5),螺旋与后两者比较均P<0.001;放射状序列优于TSE(P<0.001)。
  • 螺旋序列伪影评分4(3.75-4),放射状序列3.5(3-4),TSE 3(2.75-3.25),螺旋和放射状均较TSE伪影少(均P<0.001)。
  • 螺旋序列病灶显示评分4(4-5),优于放射状序列4(3-5)(P=0.01)和TSE 4(3-4)(P=0.04)。
  • 神经根可见性评分螺旋序列3(3-4)、放射状序列4(3-4),均优于TSE 1.5(1-2)(均P<0.001)。
  • 每例患者可见神经根数目螺旋序列4(2.75-8)、放射状序列4(3.75-7.25),均多于TSE 2(0-4)(均P<0.001)。

诊断标准与关键数值

  • 定性分析采用4分或5分Likert量表,评估整体图像质量、伪影、病灶显示及神经根可见性。
  • 读者间一致性范围从中等(α=0.639)到几乎完美(α=0.967)。
  • 椎旁肌肉变异系数(CVPM)和脊髓变异系数(CVSC)在螺旋序列上显著低于放射状序列和TSE(P<0.001,P=0.04);放射状序列CVPM和CVSC低于TSE(P<0.001,P=0.01)。

临床应用与阅片要点

  • 螺旋3D GRE序列可在较短时间内提供优于常规TSE的脊柱增强抑脂T1WI图像质量,适合用于需要快速扫描的增强脊柱MRI。
  • 螺旋序列对病灶显示和神经根可见性的评分均较高,阅片时可能更易识别强化病灶及神经根结构。
  • 放射状3D GRE序列在神经根可见性方面与螺旋序列相当,但病灶显示评分略低,选择序列时需结合临床关注点。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Pulse sequences with non-Cartesian k-space sampling enable improved imaging in anatomical areas with high degrees of motion artifacts. We analyzed a novel spiral 3-dimensional (3D) gradient echo (GRE) magnetic resonance imaging (MRI) sequence ("spiral," 114.7 ± 11 seconds) and compared it with a radial 3D GRE ("vane," 216.7 ± 2 seconds) and a conventional Cartesian 2D turbo spin echo (TSE) sequence ("TSE," 266.7 ± 82 seconds) for contrast-enhanced fat-suppressed T1-weighted spine imaging.

MATERIALS AND METHODS: Forty consecutive patients referred for contrast-enhanced MRI were prospectively scanned with all 3 sequences. A qualitative analysis was performed by 3 readers using 4- or 5-point Likert scales to independently grade images in terms of overall image quality, occurrence of artifacts, lesion conspicuity, and conspicuity of nerve roots. The numbers of visible nerve roots per sequence and patient were counted in consensus. Coefficient of variation measurements were performed for the paravertebral musculature (CVPM) and the spinal cord (CVSC).

RESULTS: Spiral (median [interquartile range], 5 [4-5]) exhibited improved overall image quality in comparison to TSE (3 [3-4]) and vane (4 [4-5]; both P < 0.001). Vane surpassed TSE in terms of overall image quality (P < 0.001). Spiral (4 [3.75-4]) and vane (3.5 [3-4]) presented with less artifacts than TSE (3 [2.75-3.25]; both P < 0.001). Spiral (4 [4-5]) outperformed vane (4 [3-5]; P = 0.01) and TSE (4 [3-4]; P = 0.04) in terms of lesion conspicuity. Conspicuity of nerve roots was superior on spiral (3 [3-4]) and vane (4 [3-4]) when compared with TSE (1.5 [1-2]; both P < 0.001). Readers discerned significantly more nerve roots on spiral (4 [2.75-8]) and vane (4 [3.75-7.25]) images when compared with TSE (2 [0-4]; both P < 0.001). Interreader agreement ranged from moderate (α = 0.639) to almost perfect (α = 0.967). CVPM and CVSC were significantly lower on spiral as compared with vane and TSE (P < 0.001, P = 0.04). Vane exhibited lower CVPM and CVSC than TSE (P < 0.001, P = 0.01).

CONCLUSIONS: A novel spiral 3D GRE sequence improves contrast-enhanced fat-suppressed T1-weighted spinal imaging qualitatively and quantitatively in comparison with a conventional Cartesian 2D TSE sequence and to a lesser extent with a radial 3D GRE sequence at shorter scan times.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Sartoretti E, Sartoretti T, van Smoorenburg L, et al. Qualitative and Quantitative Analysis of a Spiral Gradient Echo Sequence for Contrast-Enhanced Fat-Suppressed T1-Weighted Spine Magnetic Resonance Imaging. Invest Radiol. 2021. PMID: 33653993. doi:10.1097/RLI.0000000000000770

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。