SENSE与压缩SENSE加速因子对影像组学特征可重复性的影响
研究纳入14名健康志愿者,在3D T1WI上比较SENSE与压缩SENSE(CS)不同加速因子(5.5、6.8、9.7)下影像组学特征相对于原始图像(SENSE加速因子3.5)的可重复性。结果显示加速因子越高,CCC>0.85的特征比例越低(p<.001);SENSE的特征可重复性比例高于CS(6.7-7.3% vs 4.4-5.0%,p<.001)。GLRLM的run percentage结合wavelet D被识别为最可重复的特征。
要点
- 加速因子升高会降低SENSE和CS影像组学特征的可重复性,阅片时需注意。
- SENSE的特征可重复性比例高于CS(6.7-7.3% vs 4.4-5.0%)。
- GLRLM的run percentage(wavelet D)在最高加速因子下仍可重复。
关键影像表现/征象
- 评估了8个解剖位置:脑实质、唾液腺、咬肌、舌、咽黏膜间隙、眼球。
诊断标准与关键数值
- 以SENSE加速因子3.5的原始图像为参考,CCC>0.85定义为可重复。
- SENSE中CCC>0.85的特征比例为6.7-7.3%,CS中为4.4-5.0%(p<.001)。
- 在所有解剖位置,加速因子越高,CCC>0.85的特征比例越低(p<.001)。
- GLRLM的run percentage(wavelet D)在SENSE和CS加速因子9.7时,在最多解剖位置显示CCC>0.85。
临床应用与阅片要点
- 使用SENSE或CS进行影像组学研究时,加速因子选择可能影响特征可重复性。
- GLRLM的run percentage(wavelet D)在较高加速因子下仍可重复,可考虑作为候选特征。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the impact of acceleration factors on reproducibility of radiomic features in sensitivity encoding (SENSE) and compressed SENSE (CS), compare between SENSE and CS, and identify reproducible radiomic features.
METHODS: Three-dimensional turbo spin echo T1-weighted imaging was performed in 14 healthy volunteers (mean age, 57 years; range, 33-67 years; 7 men) under SENSE and CS with accelerator factors of 5.5, 6.8, and 9.7. Eight anatomical locations (brain parenchyma, salivary glands, masseter muscle, tongue, pharyngeal mucosal space, eyeballs) were evaluated. Reproducibility of radiomic features was evaluated by calculating concordance correlation coefficient (CCC) in reference to the original image (SENSE with acceleration factor of 3.5). Reproducibility of radiomic features among acceleration factors and between SENSE and CS was compared.
RESULTS: Proportion of radiomic features with CCC > 0.85 in reference to the original image was lower with higher acceleration factors in both SENSE and CS across all anatomical locations (p < .001). Proportion of radiomic features with CCC > 0.85 in reference to the original image was higher in SENSE compared with CS (SENSE, 6.7-7.3% vs CS, 4.4-5.0%; p < .001). Run percentage of gray-level run-length matrix (GLRLM) with wavelet D showed CCC > 0.85 in reference to the original image in both SENSE and CS at acceleration factor of 9.7 in the highest number of anatomical locations.
CONCLUSIONS: Higher acceleration factors resulted in lower reproducibility of radiomic features in both SENSE and CS, and SENSE showed higher reproducibility of radiomic features than CS in reference to the original image. Run percentage of GLRLM with wavelet D was identified as the most reproducible feature.
KEY POINTS: • Reproducibility of radiomic features in reference to the original image was lower with higher acceleration factors in both sensitivity encoding (SENSE) and compressed SENSE (CS) across all anatomical locations (p < .001). • SENSE showed higher proportions of radiomic features with CCC > 0.85 in reference to the original image (SENSE, 6.7-7.3% vs CS, 4.4-5.0%; p < .001) compared with CS. • Run percentage of gray-level run-length matrix (GLRLM) with wavelet D showed CCC > 0.85 in reference to the original image in both SENSE and CS with the highest acceleration factor.
引用
- Kim M, Jung SC, Park JE, et al. Reproducibility of radiomic features in SENSE and compressed SENSE: impact of acceleration factors. Eur Radiol. 2021. PMID: 33733690. doi:10.1007/s00330-021-07760-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。