深度卷积神经网络辅助解读脑[18F]DOPA PET/CT诊断帕金森病
本研究分析2016至2018年98例接受脑[18F]DOPA PET/CT的患者,其中43例有黑质纹状体神经退行性变、55例为阴性对照,比较3D卷积神经网络(CNN)与基于纹状体-枕叶比值(SOR)的手动区域分析的诊断表现。3D CNN在29例测试集上敏感度100%、特异度89%、阴性预测值100%、阳性预测值85%、准确率93%;被CNN假阳性的2例其SOR值≤阴性对照分布的第5百分位。
要点
- 3D CNN在29例测试集上诊断黑质纹状体神经退行性变的敏感度100%、特异度89%、准确率93%。
- CNN假阳性的2例SOR值≤阴性对照分布第5百分位,提示半定量SOR分析可辅助复核。
- 脑[18F]DOPA PET/CT是识别黑质纹状体神经退行性变的敏感诊断工具。
核心结论
- 3D卷积神经网络能够正确解读脑[18F]DOPA PET/CT图像,识别帕金森病患者。
研究设计与样本
- 研究分析了2016至2018年接受[18F]DOPA PET/CT的患者,仅纳入随访至少2年且神经科诊断明确的病例。
- 共纳入98例患者,其中43例存在黑质纹状体变性、55例为阴性对照。
- 两名阅片者将PET/CT图像判读为阳性或阴性,作为参考标准。
- 3D CNN在69例患者上训练、在29例患者上测试(训练与测试分别占2/3和1/3)。
- 区域分析通过在T1加权3D MRI图像上勾画感兴趣区进行,[18F]DOPA PET图像先与MRI配准。
诊断标准与关键数值
- 3D CNN在29例测试集上的敏感度100%、特异度89%、阴性预测值100%、阳性预测值85%、准确率93%。
- 区域分析采用纹状体-枕叶比值(SOR),3D CNN假阳性的2例其SOR值≤阴性病例分布的第5百分位。
临床应用与阅片要点
- 3D CNN可用于辅助解读脑[18F]DOPA PET/CT,识别黑质纹状体神经退行性变患者。
- 对CNN判为阳性的病例,可结合SOR半定量分析复核,本研究中2例假阳性病例的SOR值≤阴性病例分布的第5百分位。
- 半定量评估图像有助于更有信心地解读PET表现。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To test the performance of a 3D convolutional neural network (CNN) in analysing brain [18F]DOPA PET/CT in order to identify patients with nigro-striatal neurodegeneration. We evaluated the robustness of the 3D CNN by testing it against a manual regional analysis of the striata by using a striatal-to-occipital ratio (SOR).
METHODS: We analyzed patients who had undergone [18F]DOPA PET/CT from 2016 to 2018. Two examiners interpreted PET/CT images as positive or negative. Only patients with at least 2 years of follow-up and an ascertained neurological diagnosis were included. A 3D CNN was developed to evaluate [18F]DOPA PET/CT and refine the diagnosis of movement disorder. This system required training and testing, which were carried out on 2/3 and 1/3 of patients, respectively. A regional analysis was also conducted by drawing region of interest on T1-weighted 3D MRI scans, on which the [18F]DOPA PET images were first co-registered.
RESULTS: Ninety-eight patients were enrolled: 43 presented nigro-striatal degeneration and 55 negative cases used as controls. After training on 69 patients, the diagnostic performance of the 3D CNN was then calculated in 29 patients. Sensitivity, specificity, negative predictive value, positive predictive value and accuracy were 100%, 89%, 100%, 85% and 93%, respectively. When we compared the 3D CNN results with the SOR analysis, we found that the two patients falsely classified as positive by the 3D CNN procedure showed SOR values ≤ 5th percentile of the negative cases' distribution.
CONCLUSIONS: 3D CNNs are able to interpret [18F]DOPA PET/CT properly, revealing patients affected by Parkinson's disease.
KEY POINTS: • [18F]DOPA PET/CT is a sensitive diagnostic tool to identify patients with nigro-striatal neurodegeneration. • A semiquantitative evaluation of the images allows a more confident interpretation of the PET findings. • 3D convolutional neural network allows an accurate interpretation of 18F-DOPA PET/CT images, revealing patients affected by Parkinson's disease.
引用
- Piccardo A, Cappuccio R, Bottoni G, et al. The role of the deep convolutional neural network as an aid to interpreting brain [18F]DOPA PET/CT in the diagnosis of Parkinson's disease. Eur Radiol. 2021. PMID: 33686474. doi:10.1007/s00330-021-07779-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。