疑似未确诊COVID-19的多学科评估:胸部CT与WHO建议的比较
该临床审计回顾性分析90例SARS-CoV-2 RT-PCR初检阴性、疑似COVID-19的患者,评估包括胸部CT在内的检查流程与WHO建议的依从性。对WHO建议的依从率为75%,79例胸部CT对COVID-19的阳性、不确定和阴性率分别为3.79%、24.1%和72.15%。初检拭子假阴性率为16.67%,原文认为需进一步证据以确定胸部CT在此情境下的效用。
要点
- 79例胸部CT中COVID-19阳性率3.79%、不确定率24.1%、阴性率72.15%。
- 初检SARS-CoV-2 RT-PCR拭子假阴性率为16.67%,复检者假阴性率为5.1%。
- 对WHO相关建议的依从率为75%,原文认为需进一步证据确定胸部CT效用。
核心结论
- 对WHO相关指南的依从率为75%,初检拭子假阴性率为16.67%。
- 原文认为需进一步证据以完全确定胸部CT在初检RT-PCR假阴性背景下诊断COVID-19的效用。
研究设计与样本
- 临床审计,回顾性病历审查,纳入90例疑似COVID-19且SARS-CoV-2 RT-PCR阴性的患者,与WHO建议进行比较。
- 患者中男性52例(57.78%)、女性38例(42.22%),中位年龄69岁(范围20-96岁)。
- 共79例胸部CT检查用于明确诊断,原文未报告设备或序列具体信息。
关键影像表现/征象
- 79例胸部CT对COVID-19的阳性率为3.79%、不确定率为24.1%、阴性率为72.15%。
- 3例患者拭子结果不一致,初始阴性而后续SARS-CoV-2阳性。
诊断标准与关键数值
- 79例胸部CT对COVID-19的阳性、不确定、阴性率分别为3.79%、24.1%、72.15%。
- 复检患者的SARS-CoV-2 RT-PCR假阴性率为5.1%。
- 结合不一致RT-PCR拭子结果、阳性影像以及因影像不确定且症状高度一致而按COVID-19阳性治疗的患者,初检SARS-CoV-2 RT-PCR拭子的假阴性率为16.67%。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文结论指出需进一步证据以完全确定胸部CT在初检RT-PCR假阴性背景下诊断COVID-19的效用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To report an audit of the evaluation of suspected, unconfirmed cases of COVID-19 including chest computed tomography (CT), as compared to World Health Organization recommendations.
METHODS: A clinical audit was undertaken examining the evaluation of patients with suspected COVID-19 with negative SARS-CoV-2 reverse transcriptase polymerase chain reaction (RT-PCR) results, with comparison to WHO recommendations. A retrospective chart review was undertaken for 90 patients examining investigations, in particular CT, used to clarify the diagnosis.
RESULTS: Ninety patients underwent additional investigation. Seventy-five per cent adherence to WHO recommendations was observed. Fifty-two men (57.78%) and 38 (42.22%) women were investigated, with a median age of 69 years (range 20-96 years). Seventy-nine chest CT examinations demonstrated positive, indeterminate, and negative rates for COVID-19 of 3.79%, 24.1%, and 72.15% respectively. Three patients had discordant swab results with initially negative and subsequently positive results for SARS-CoV-2, resulting in false-negative rates of 5.1% for those retested. Combining discordant RT-PCR swab results, positive radiology, and patients treated as COVID-19-positive due to indeterminate radiology and highly consistent symptoms, resulted in a false-negative rate for initial SARS-CoV-2 RT-PCR swabs of 16.67%.
CONCLUSION: Seventy-five per cent compliance with relevant WHO guidance and a false-negative rate for initial swabs of 16.67% was demonstrated. Further evidence is needed to fully determine the utility of chest CT in the diagnosis of COVID-19 in the context of initial false-negative RT-PCR results.
引用
- McGrath J, Kenny C, Smyth H, et al. A multidisciplinary evaluation of suspected, non-confirmed cases of COVID-19 including chest CT, as compared to World Health Organization recommendations. Clin Radiol. 2021. PMID: 33691952. doi:10.1016/j.crad.2021.02.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。