指南与共识胸部CT

RSNA专家共识CT报告分类对疑似COVID-19的诊断准确性:意大利单中心经验

Diagnostic Accuracy of North America Expert Consensus Statement on Reporting CT Findings in Patients Suspected of Having COVID-19 Infection: An Italian Single-Center Experience.
指南 / 共识 · Radiol Cardiothorac Imaging · 2020-07-23

该单中心回顾性研究纳入2020年2月27日至3月27日569例疑似COVID-19患者的薄层CT,按RSNA四分类(典型、不确定、非典型、阴性)与RT-PCR对照分析460例。典型模式对COVID-19的敏感度为71.6%、特异度为91.6%、阳性预测值为87.8%;非典型和阴性模式对非COVID-19的阳性预测值分别为89.6%和86.2%。不确定模式中血管增粗征在COVID-19患者中最常见(86.1%,P < .001)。

要点

  • 典型模式对COVID-19的敏感度为71.6%、特异度为91.6%、阳性预测值为87.8%。
  • 非典型和阴性模式对非COVID-19的阳性预测值分别为89.6%和86.2%。
  • 不确定模式中血管增粗征在COVID-19患者中最常见,占86.1%(P < .001)。

关键影像表现/征象

  • 典型模式(n = 172)对COVID-19的敏感度为71.6%、特异度为91.6%、阳性预测值为87.8%。
  • 非典型模式(n = 67)对非COVID-19的阳性预测值为89.6%,阴性模式(n = 123)对非COVID-19的阳性预测值为86.2%。
  • 不确定模式(n = 98)无特异性,但血管增粗征在COVID-19患者中最常见,占86.1%(P < .001)。

诊断标准与关键数值

  • RSNA四分类:典型、不确定、非典型、阴性。
  • 典型模式对COVID-19的敏感度为71.6%、特异度为91.6%、阳性预测值为87.8%。
  • 非典型模式对非COVID-19的阳性预测值为89.6%,阴性模式对非COVID-19的阳性预测值为86.2%。
  • 不确定模式中血管增粗征在COVID-19患者中占86.1%(P < .001)。
  • 观察者间一致性:典型和阴性模式为good,不确定和非典型模式为fair(κ = 0.5;P = .002)。

临床应用与阅片要点

  • 典型、非典型和阴性模式与RT-PCR结果高度相关,可用于标准化诊断假设。
  • 不确定模式中分析血管增粗征可能有助于解读影像特征。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the diagnostic accuracy of the four standardized categories for CT reporting proposed by the Radiological Society of North America (RSNA) to support a faster triage compared with real-time reverse-transcription polymerase chain reaction (RT-PCR), which is the reference standard for suspected coronavirus disease 2019 (COVID-19), but has long reporting time (6-48 hours).

MATERIALS AND METHODS: A retrospective analysis of 569 thin-section CT examinations performed for patients suspected of having COVID-19 from February 27 to March 27, 2020 (peak of infection in Italy) was conducted. The imaging pattern was classified according to the statement by the RSNA as "typical," "indeterminate," "atypical," and "negative" and compared with RT-PCR for 460 patients. Interobserver variability in reporting between a senior and a junior radiologist was evaluated. Use of the vascular enlargement sign in indeterminate cases was also assessed.

RESULTS: The diagnosis of COVID-19 was made in 45.9% (211/460) of patients. The "typical" pattern (n = 172) showed a sensitivity of 71.6%, a specificity of 91.6%, and a positive predictive value of 87.8% for COVID-19. The "atypical" (n = 67) and "negative" (n = 123) pattern demonstrated a positive predictive value of 89.6% and 86.2% for non-COVID-19, respectively. The "indeterminate" (n = 98) pattern was nonspecific, but vascular enlargement was most frequently found in patients with COVID-19 (86.1%; P < .001). Interobserver agreement was good for the "typical" and "negative" pattern and fair for "indeterminate" and "atypical" (κ = 0.5; P = .002).

CONCLUSION: In an epidemic setting, the application of the four categories proposed by the RSNA provides a standardized diagnostic hypothesis, strongly linked to the RT-PCR results for the "typical," "atypical," and "negative" pattern. In the "indeterminate" pattern, the analysis of the vascular enlargement sign could facilitate the interpretation of imaging features.© RSNA, 2020.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Ciccarese F, Coppola F, Spinelli D, et al. Diagnostic Accuracy of North America Expert Consensus Statement on Reporting CT Findings in Patients Suspected of Having COVID-19 Infection: An Italian Single-Center Experience. Radiol Cardiothorac Imaging. 2020. PMID: 33778611. doi:10.1148/ryct.2020200312

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。