RSNA新冠胸部CT报告专家共识指南的多读者验证研究
该研究回顾性纳入89例因疑似新冠行胸部CT的患者,由9名不同年资放射科医生按RSNA指南分类,以RT-PCR为金标准。典型表现平均敏感度86%、特异度80.2%,典型加不确定表现敏感度97.5%、特异度54.7%,读者间一致性尚可。
要点
- 典型表现诊断新冠平均敏感度86%、特异度80.2%,典型加不确定表现敏感度97.5%、特异度54.7%。
- 不同年资读者间一致性kappa 0.43至0.86,总一致率79.6%。
- 分类不确定主要源于外周分布判断困难、多发病灶或病变轻微。
核心结论
- 典型表现类别平均敏感度86%、特异度80.2%,读者间一致性合理且不同经验水平间可重复性良好。
研究设计与样本
- 金标准为一次阳性或两次阴性RT-PCR检测。
- 由9名读者(6名胸科放射专科培训医师和3名放射科住院培训医师)按RSNA指南评估。
诊断标准与关键数值
- 典型表现平均敏感度86%(范围72%-94%)、平均特异度80.2%(范围75%-93%)。
- 典型加不确定表现敏感度97.5%(范围94%-100%)、特异度54.7%(范围37%-62%)。
- 不同培训水平间一致率60%-86%,kappa 0.43-0.86。
- 801次观察中163次分歧,总一致率79.6%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: RSNA expert consensus guidelines provide a framework for reporting CT findings related to COVID-19, but have had limited multireader validation.
PURPOSE: To assess the performance of the RSNA guidelines and quantify interobserver variability in application of the guidelines in patients undergoing chest CT for suspected COVID-19 pneumonia.
MATERIALS AND METHODS: A retrospective search from 1/15/20 to 3/30/20 identified 89 consecutive CT scans whose radiological report mentioned COVID-19. One positive or two negative RT-PCR tests for COVID-19 were considered the gold standard for diagnosis. Each chest CT scan was evaluated using RSNA guidelines by 9 readers (6 fellowship trained thoracic radiologists and 3 radiology resident trainees). Clinical information was obtained from the electronic medical record.
RESULTS: There was strong concordance of findings between radiology training levels with agreement ranging from 60 to 86% among attendings and trainees (kappa 0.43 to 0.86). Sensitivity and specificity of "typical" CT findings for COVID-19 per the RSNA guidelines were on average 86% (range 72%-94%) and 80.2% (range 75-93%), respectively. Combined "typical" and "indeterminate" findings had a sensitivity of 97.5% (range 94-100%) and specificity of 54.7% (range 37-62%). A total of 163 disagreements were seen out of 801 observations (79.6% total agreement). Uncertainty in classification primarily derived from difficulty in ascertaining peripheral distribution, multiple dominant disease processes, or minimal disease.
CONCLUSION: The "typical appearance" category for COVID-19 CT reporting has an average sensitivity of 86% and specificity rate of 80%. There is reasonable interreader agreement and good reproducibility across various levels of experience.
引用
- Som A, Lang M, Yeung T, et al. Implementation of the Radiological Society of North America Expert Consensus Guidelines on Reporting Chest CT Findings Related to COVID-19: A Multireader Performance Study. Radiol Cardiothorac Imaging. 2020. PMID: 33778625. doi:10.1148/ryct.2020200276
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。