指南与共识胸部CT

RSNA新冠胸部CT报告专家共识指南的多读者验证研究

Implementation of the Radiological Society of North America Expert Consensus Guidelines on Reporting Chest CT Findings Related to COVID-19: A Multireader Performance Study.
指南 / 共识 · Radiol Cardiothorac Imaging · 2020-09-10

该研究回顾性纳入89例因疑似新冠行胸部CT的患者,由9名不同年资放射科医生按RSNA指南分类,以RT-PCR为金标准。典型表现平均敏感度86%、特异度80.2%,典型加不确定表现敏感度97.5%、特异度54.7%,读者间一致性尚可。

要点

  • 典型表现诊断新冠平均敏感度86%、特异度80.2%,典型加不确定表现敏感度97.5%、特异度54.7%。
  • 不同年资读者间一致性kappa 0.43至0.86,总一致率79.6%。
  • 分类不确定主要源于外周分布判断困难、多发病灶或病变轻微。

核心结论

  • 典型表现类别平均敏感度86%、特异度80.2%,读者间一致性合理且不同经验水平间可重复性良好。

研究设计与样本

  • 金标准为一次阳性或两次阴性RT-PCR检测。
  • 由9名读者(6名胸科放射专科培训医师和3名放射科住院培训医师)按RSNA指南评估。

诊断标准与关键数值

  • 典型表现平均敏感度86%(范围72%-94%)、平均特异度80.2%(范围75%-93%)。
  • 典型加不确定表现敏感度97.5%(范围94%-100%)、特异度54.7%(范围37%-62%)。
  • 不同培训水平间一致率60%-86%,kappa 0.43-0.86。
  • 801次观察中163次分歧,总一致率79.6%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: RSNA expert consensus guidelines provide a framework for reporting CT findings related to COVID-19, but have had limited multireader validation.

PURPOSE: To assess the performance of the RSNA guidelines and quantify interobserver variability in application of the guidelines in patients undergoing chest CT for suspected COVID-19 pneumonia.

MATERIALS AND METHODS: A retrospective search from 1/15/20 to 3/30/20 identified 89 consecutive CT scans whose radiological report mentioned COVID-19. One positive or two negative RT-PCR tests for COVID-19 were considered the gold standard for diagnosis. Each chest CT scan was evaluated using RSNA guidelines by 9 readers (6 fellowship trained thoracic radiologists and 3 radiology resident trainees). Clinical information was obtained from the electronic medical record.

RESULTS: There was strong concordance of findings between radiology training levels with agreement ranging from 60 to 86% among attendings and trainees (kappa 0.43 to 0.86). Sensitivity and specificity of "typical" CT findings for COVID-19 per the RSNA guidelines were on average 86% (range 72%-94%) and 80.2% (range 75-93%), respectively. Combined "typical" and "indeterminate" findings had a sensitivity of 97.5% (range 94-100%) and specificity of 54.7% (range 37-62%). A total of 163 disagreements were seen out of 801 observations (79.6% total agreement). Uncertainty in classification primarily derived from difficulty in ascertaining peripheral distribution, multiple dominant disease processes, or minimal disease.

CONCLUSION: The "typical appearance" category for COVID-19 CT reporting has an average sensitivity of 86% and specificity rate of 80%. There is reasonable interreader agreement and good reproducibility across various levels of experience.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Som A, Lang M, Yeung T, et al. Implementation of the Radiological Society of North America Expert Consensus Guidelines on Reporting Chest CT Findings Related to COVID-19: A Multireader Performance Study. Radiol Cardiothorac Imaging. 2020. PMID: 33778625. doi:10.1148/ryct.2020200276

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。