肺动脉CTA检测肺栓塞:管电压与对比剂注射速率对诊断信心的影响
回顾性分析401例肺动脉CTA图像,比较三种扫描方案(120kVp/4cc/s、120kVp/5cc/s、100kVp/4cc/s)的诊断信心及图像质量与辐射剂量。120kVp/5cc/s方案高诊断信心比例达84%,高于120kVp/4cc/s的65%和100kVp方案的65%(P<0.004)。100kVp方案辐射剂量更低、图像噪声更高、SNR更低,但肺动脉衰减值相等或更高。结论认为100kVp/4cc/s可维持诊断信心并降低辐射暴露,但未达到120kVp/5cc/s的高信心水平。
要点
- 120kVp/5cc/s方案高诊断信心比例最高(84%),优于120kVp/4cc/s和100kVp/4cc/s(均为65%)。
- 100kVp/4cc/s方案辐射剂量更低,但图像噪声更高、SNR更低,肺动脉衰减值相等或更高。
- 降低管电压至100kVp并保持4cc/s可维持诊断信心并减少辐射,但未达到120kVp/5cc/s的信心水平。
诊断标准与关键数值
- 120kVp/5cc/s方案高诊断信心比例为84%,高于120kVp/4cc/s方案的65%和100kVp/4cc/s方案的65%(P<0.004)。
- 100kVp/4cc/s方案与120kVp方案相比,辐射剂量更低、图像噪声更高、SNR更低,但肺动脉衰减值相等或更高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Pulmonary CTA is the current standard method to assess for suspected pulmonary embolism. In some instances, the test results in low confidence interpretations. Our purpose was to compare the diagnostic confidence for three different scan protocols.
MATERIALS AND METHODS: Pulmonary CTA images from 401 patients were retrospectively analyzed. 202 studies used a tube voltage of 120 kVp and a contrast injection rate of 4 cc/s, 99 studies 120 kVp and 5 cc/s, and 100 studies 100 kVp and 4 cc/s. The level of diagnostic confidence was extracted from the final clinical reports. For each study, attenuation of the pulmonary artery, image noise, signal-to-noise ratio (SNR), and radiation dose were compared.
RESULTS: The 120 kVp, 5 cc/s protocol resulted in high diagnostic confidence in 84% of cases, more than with the 120 kVp, 4cc/s (65%) and the 100 kVp protocol (65%, p < 0.004). The 100 kVp protocol had a lower radiation dose, higher image noise, lower SNR, but equal and higher attenuation values of the pulmonary artery.
CONCLUSION: The reduction of tube voltage to 100 kVp at 4 cc/s maintains diagnostic confidence with lower radiation exposure, but does not equal the higher confidence achieved with 120 kVp at 5cc/s.
引用
- Knollmann F, Chu L, Lang JA, et al. CT Angiography for the Detection of Pulmonary Embolism: Role of Tube Voltage and Contrast Injection Rate on Diagnostic Confidence. Acad Radiol. 2021. PMID: 33602596. doi:10.1016/j.acra.2021.01.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。