高帧率超声造影鉴别胆囊腺瘤与胆固醇性息肉的价值
本研究纳入94例接受腹腔镜胆囊切除术的胆囊息肉样病变患者,术前分别行超声造影(CEUS)与高帧率超声造影(H-CEUS)检查,比较两者灌注特征及鉴别胆囊腺瘤与胆固醇性息肉的诊断价值。结果显示H-CEUS可观察到两组病变血管类型差异(p<0.05),而CEUS未能显示差异(p>0.05),H-CEUS鉴别诊断价值优于CEUS。
要点
- H-CEUS可显示胆囊腺瘤与胆固醇性息肉在动脉期微血管形态上的差异。
- 常规CEUS未能显示胆囊腺瘤与胆固醇性息肉的血管类型差异。
- H-CEUS鉴别胆囊腺瘤与胆固醇性息肉的诊断价值优于CEUS。
关键影像表现/征象
- H-CEUS上胆囊腺瘤与胆固醇性息肉病变的血管类型存在差异(p<0.05)。
- CEUS上胆囊腺瘤与胆固醇性息肉病变的血管类型无差异(p>0.05)。
- 胆固醇性息肉组中CEUS与H-CEUS所显示的血管类型无差异(p>0.05)。
- 胆囊腺瘤组中CEUS与H-CEUS所显示的血管类型存在差异(p<0.05)。
- H-CEUS有助于准确评价胆囊息肉样病变动脉期的微血管形态。
诊断标准与关键数值
- H-CEUS鉴别胆囊腺瘤与胆固醇性息肉的诊断价值优于CEUS。
临床应用与阅片要点
- H-CEUS通过提高帧率改善时间分辨率,有助于在动脉期准确评价胆囊息肉样病变的微血管形态。
- 作者认为H-CEUS可能为胆囊息肉样病变患者治疗方式的选择提供有效影像手段。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the diagnostic value of high frame rate contrast-enhanced ultrasound (H-CEUS) in distinguishing gallbladder adenomas from cholesterol polyp lesions with that of CEUS.
METHODS: This study enrolled 94 patients with gallbladder polyp lesions (GPLs) who underwent laparoscopic cholecystectomy. CEUS and H-CEUS were performed before surgery. The perfusion features of GPLs and the final diagnosis as determined by both technologies were compared.
RESULTS: There were differences in vascular types between gallbladder adenomas and cholesterol polyp lesions observed on H-CEUS (p < 0.05), while there were no differences in vascular types between gallbladder adenomas and cholesterol polyp lesions observed on CEUS (p > 0.05). In the cholesterol polyp lesion group, there were no differences in vascular types between CEUS and H-CEUS (p > 0.05), while the vascular types were different between CEUS and H-CEUS in the gallbladder adenoma group (p < 0.05). The diagnostic value of H-CEUS in distinguishing gallbladder adenomas from cholesterol polyp lesions was better than that of CEUS.
CONCLUSIONS: H-CEUS improved the time resolution by increasing the frame rate, which helped to accurately reflect the difference in the microcirculation of GPLs and improved the ability of a differential diagnosis between cholesterol polyp lesions and adenomas. H-CUES may provide an effective means of imaging for patients with GPLs regarding the choice of treatment options.
KEY POINTS: • High frame rate CEUS improves the time resolution of CEUS by increasing the frame rate. • High frame rate CEUS is helpful to accurately evaluate the microvascular morphology of a gallbladder polyp lesion in the arterial phase. • High frame rate CEUS helps patients with gallbladder polyp lesions to choose the appropriate treatment means.
引用
- Fei X, Li N, Zhu L, et al. Value of high frame rate contrast-enhanced ultrasound in distinguishing gallbladder adenoma from cholesterol polyp lesion. Eur Radiol. 2021. PMID: 33569621. doi:10.1007/s00330-021-07730-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。