文献速递胸部儿科影像MR

儿童3-T MRI自由呼吸快速T2加权MultiVane XD序列评估大气道的前瞻性研究

Prospective Evaluation of Free-Breathing Fast T2-Weighted MultiVane XD Sequence at 3-T MRI for Large Airway Assessment in Pediatric Patients.
PubMed 文献 · AJR Am J Roentgenol · 2021-02-03

前瞻性纳入40例因非颈胸或大气道适应症转诊的连续儿童患者,在3-T MRI上采用自由呼吸快速T2加权MultiVane XD序列行三平面成像,由两名儿科放射科医师独立评估六个层面大气道显示情况。结果显示 reviewer 1 在38例(95.0%)、reviewer 2 在37例(92.5%)至少一个平面上获得高质量大气道图像,矢状面图像质量最佳、伪影最少,两位医师间一致性在矢状面几乎完全一致(κ=1),作者认为该序列技术上可行且有前景。

要点

  • 自由呼吸快速T2加权MultiVane XD序列可在3-T MRI上用于儿童大气道评估,95.0%检查至少一个平面获得高质量图像。
  • 矢状面图像质量最佳、伪影最少,依次为冠状面和轴面。
  • 两位医师图像质量评估一致性矢状面κ=1、冠状面κ=0.96、轴面κ=0.81。

关键影像表现/征象

  • 高质量大气道MR图像在至少一个平面上由 reviewer 1 于38例检查(95.0%)、reviewer 2 于37例检查(92.5%)获得。
  • 图像质量最佳、伪影最少的平面为矢状面,其次为冠状面,再次为轴面。

诊断标准与关键数值

  • 两位放射科医师对MR图像质量评估的一致性:矢状面κ=1,冠状面κ=0.96,轴面κ=0.81。
  • McNemar检验与组内相关系数得出相似结果。

临床应用与阅片要点

  • 作者认为该自由呼吸快速T2加权MultiVane XD序列在3-T MRI上可用于日常临床实践中评估儿童大气道。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of our study was to prospectively evaluate the technical feasibility of the free-breathing fast T2-weighted MultiVane XD sequence (sequence with non-Cartesian k-space filling using radial rectangular blades) at 3-T MRI for large airway assessment in pediatric patients. SUBJECTS AND METHODS. Forty consecutive pediatric patients (23 boys and 17 girls; age range, 5-15 years) referred for MRI examination for indications not related to neck, chest, or large airway disorders were enrolled in this prospective research study. All children underwent MRI in three planes using a free-breathing fast T2-weighted MultiVane XD sequence at 3-T MRI. The MR images were assessed by two pediatric radiologists independently for visualization of the large airways at six levels. The quality of the MR images was assessed and graded. Interobserver agreement between two radiologists was assessed using the kappa test, McNemar test, and intraclass correlation coefficients. RESULTS. High-quality MR images of the large airways were obtained in at least one plane in 38 MRI examinations (95.0%) by reviewer 1 and 37 MRI examinations (92.5%) by reviewer 2. Best-quality MR images with the least artifacts were seen in the sagittal plane followed by the coronal plane and the axial plane. The kappa test of agreement showed almost-perfect agreement between the two radiologists for MR image quality in the sagittal (κ = 1), coronal (κ = 0.96), and axial (κ = 0.81) planes. The McNemar test and intraclass correlation coefficients revealed similar results. CONCLUSION. The free-breathing fast T2-weighted MultiVane XD sequence at 3-T MRI is a technically feasible and promising new MRI technique for evaluating the large airways of pediatric patients in daily clinical practice.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Sodhi KS, Bhatia A, Lee EY, et al. Prospective Evaluation of Free-Breathing Fast T2-Weighted MultiVane XD Sequence at 3-T MRI for Large Airway Assessment in Pediatric Patients. AJR Am J Roentgenol. 2021. PMID: 33534623. doi:10.2214/AJR.20.23225

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。